Background: To evaluate the success rate of orthodontic mini-implant (MI) in relation to implant characteristics, mainly implant distance to alveolar crestal bone (AC) and root proximity (RP) to adjacent teeth.
Methods: Two hundred sixty MIs (209 in maxilla, 51 in mandible) were categorized into success (n = 229) and failure (n = 31) groups. Distances from MI to the most adjacent tooth (DT) and to AC level (DC) were measured on periapical radiographs taken with the orthoradial projection technique. Appropriate statistical tests (chi-square, t test, logistic regression) were applied.
Results: DC measurements were statistically significantly greater in the success group (7.46 ± 1.7 mm) compared to 3.43 ± 0.81 mm in the failure group. Root proximity was not associated with miniscrew failure. Patient age, mini-implant site, and DC were significant predictors of mini-implant failure (p < 0.001), which decreased significantly with increasing age (Coef = - 0.345; p = 0.013) and when the mini-implant was placed between premolars (p = 0.028) or between premolar and first molar (p = 0.045). The probability of failure also decreased with increasing DC distance (Coef = - 3.595; p < 0.001).
Conclusion: The distance to alveolar crest was strongly associated with long-term stability. More apical placement of the MI from the crest would be compatible with a denser and thicker bucco-lingual/palatal bone level.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6512897 | PMC |
http://dx.doi.org/10.1186/s40510-019-0273-1 | DOI Listing |
BMC Oral Health
January 2025
Department of Oral and Maxillofacial Surgery, Ahmet Kelesoglu Faculty of Dentistry, Karaman, 70200, Türkiye.
Objective: This study aims to determine the anatomical relationship between the posterior superior alveolar artery (PSAA) and the lateral wall of the maxillary sinus during preoperative radiological evaluations in the posterior maxillary dental region, as well as to evaluate the prevalence of PSAA and its potential associations with sinus pathologies.
Materials And Methods: This retrospective study is based on the analysis of Cone-Beam Computed Tomography (CBCT) data from 510 sinuses of 255 patients. The visibility of the PSAA vascular canal, artery diameters, vertical distance between the alveolar crest and the artery, and the distance to the sinus floor were measured in coronal sections.
Clin Oral Investig
January 2025
Division of Prosthodontics and Implant Prosthodontics, Department of Surgical Sciences, University of Genova, Genova, Italy.
Objectives: The present systematic review aimed to evaluate if cortical bone perforation is effective in enhancing periodontal surgery and guided bone regeneration (GBR) in humans.
Materials And Methods: Electronic search was performed in PubMed, Scopus and Cochrane CENTRAL up to October 31st, 2023. Grey literature was also searched.
Clin Cosmet Investig Dent
January 2025
Al-Sabah Center, Al- Yarmouk, Baghdad, Iraq.
Purpose: The study aimed to measure the distance from the cementoenamel junction (CEJ) to the alveolar bone crest on both the buccal and lingual sides of the anterior mandibular teeth utilizing cone beam computed tomography (CBCT).
Materials And Methods: Cone-beam computed tomography (CBCT) was utilized to measure the distance between CEJ and the alveolar bone crest on both the buccal and lingual sides of the mandible's anterior teeth.
Results: The mean of the distance on buccal side for the central, lateral, and canine teeth were (1.
Comput Med Imaging Graph
January 2025
Institute of Biomedical Manufacturing and Life Quality Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China. Electronic address:
Accurate segmentation of the inferior alveolar nerve (IAN) within Cone-Beam Computed Tomography (CBCT) images is critical for the precise planning of oral and maxillofacial surgeries, especially to avoid IAN damage. Existing methods often fail due to the low contrast of the IAN and the presence of artifacts, which can cause segmentation discontinuities. To address these challenges, this paper proposes a novel approach that employs Non-Uniform Rational B-Spline (NURBS) curve shape priors into a multiscale attention network for the automatic segmentation of the IAN.
View Article and Find Full Text PDFJ Esthet Restor Dent
January 2025
Center of Advanced Dental Education, Department of Periodontics, Saint Louis University, Saint Louis, Missouri, USA.
Objectives: To investigate the correlation between gingival thickness (GT) and buccal bone thickness (BBT), as well as the effects of GT, BBT, bone crest level (BC), and tooth position on the buccal gingival margin location of maxillary teeth in the esthetic zone.
Materials And Methods: Periodontally healthy subjects with prior cone beam computed tomography and intraoral scans for dental implant planning were included. The hard and soft tissue measurements were retrospectively analyzed digitally.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!