Fabrication of Designable and Suspended Microfibers via Low-Voltage 3D Micropatterning.

ACS Appl Mater Interfaces

Department of Engineering , University of Cambridge, Trumpington Street , Cambridge CB2 1PZ , U.K.

Published: June 2019

Building two-dimensional (2D) and three-dimensional (3D) fibrous structures in the micro- and nanoscale will offer exciting prospects for numerous applications spanning from sensors to energy storage and tissue engineering scaffolds. Electrospinning is a well-suited technique for drawing micro- to nanoscale fibers, but current methods of building electrospun fibers in 3D are restrictive in terms of printed height, design of macroscopic fiber networks, and choice of polymer. Here, we combine low-voltage electrospinning and additive manufacturing as a method to pattern layers of suspended mesofibers. Layers of fibers are suspended between 3D-printed supports in situ in multiple fiber layers and designable orientations. We examine the key working parameters to attain a threshold for fiber suspension, use those behavioral observations to establish a "fiber suspension indicator", and demonstrate its utility through design of intricate suspended fiber architectures. Individual fibers produced by this method approach the micrometer/submicrometer scale, while the overall suspended 3D fiber architecture can span over a centimeter in height. We demonstrate an application of suspended fiber architectures in 3D cell culture, utilizing patterned fiber topography to guide the assembly of suspended high-cellular-density structures. The solution-based fiber suspension patterning process we report offers a unique competence in patterning soft polymers, including extracellular matrix-like materials, in a high resolution and aspect ratio. The platform could thus offer new design and manufacturing capabilities of devices and functional products by incorporating functional fibrous elements.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6613729PMC
http://dx.doi.org/10.1021/acsami.9b01258DOI Listing

Publication Analysis

Top Keywords

suspended fiber
12
micro- nanoscale
8
fiber
8
fiber suspension
8
fiber architectures
8
suspended
7
fabrication designable
4
designable suspended
4
suspended microfibers
4
microfibers low-voltage
4

Similar Publications

A refractive index (RI) and temperature dual-parameter sensor, based on a side-polished hole-assisted dual-core fiber (HADCF), has been proposed. In this sensor, SnO film has been deposited on the suspended core of HADCF by RF sputtering to produce loss mode resonance (LMR). The energy of the center core has been shown to be able to be coupled into the suspended core, taking advantage of the small distance involved and phase matching between two cores.

View Article and Find Full Text PDF

Microplastic and microfiber contamination in the Tiber River, Italy: Insights into their presence and chemical differentiation.

Mar Pollut Bull

January 2025

Institute of Aquatic Ecology, HUN-REN Centre for Ecological Research, Karolina út 29-31, H-1113 Budapest, Hungary; National Laboratory for Water Sciences and Water Security, Institute of Aquatic Ecology, HUN-REN Centre for Ecological Research, Karolina út 29-31, H-1113 Budapest, Hungary; Institute of Chemistry, Eötvös Loránd University, Pázmány Péter sétány 1/A, H1113 Budapest, Hungary. Electronic address:

Microplastics (MPs) are an emerging environmental concern, but studies on these contaminants, particularly in river ecosystems, remain scarce. Research has indicated that MPs in the environment are predominantly microfibers (MFs); however, a few studies suggest that the MFs encountered are chiefly of natural origin. In this study, we aimed to improve the understanding of MP/MFs (both plastic and natural), among microparticle (solid particles >10 μm to <5000 μm; mainly of plastic as well as natural origin) loads in the Tiber River, Italy, by analyzing the physicochemical properties of surface water and assessing the abundance and characteristics of MPs-MFs at three sites: Ponte Grillo, Aniene, and Magliana, along a 60 km stretch.

View Article and Find Full Text PDF

Hidden threat in turbid waters: Quantifying and modeling the bioaccumulation and risks of particulate metals to clams.

Environ Pollut

January 2025

Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, State Key Lab of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen, Fujian, 361102, China. Electronic address:

A major proportion of metal contaminants in aquatic environments is bound to suspended particulate matter (SPM), yet environmental monitoring typically focuses on dissolved metals, with the filtration step removing SPM. This step may inadvertently hide the potential risks posed by particulate metals. In this study, we used stable isotope tracers to quantify the contributions of SPM-bound metals to the bioaccumulation of nickel (Ni), copper (Cu), zinc (Zn), cadmium (Cd), and lead (Pb) in Ruditapes philippinarum, a widely distributed clam crucial to global aquaculture.

View Article and Find Full Text PDF

Microplastics (MPs) are ubiquitous in river and freshwater ecosystems. However, the hydraulic and hydrological mechanisms that regulate the activation and emissions of MPs from both the land surface and subsurface into rivers are not well understood. This study aims to quantify the instream MP concentration and MP load in a remote headwater catchment river (Taff Bargoed, Wales, UK), which drains the UK's largest opencast coal mine (Ffos-y-fran), over a two-year period.

View Article and Find Full Text PDF

Using lock-exchange experiments, this study investigates the transport and sedimentation of microplastics (MPs) via turbidity currents. Two hypotheses were tested: MP sedimentation is influenced by suspended sediment concentration and grain size. Utilizing flows with different sediment concentrations and grain sizes in combination with three different MPs (PET fibers, melamine, and PVC fragments), the experiments revealed distinct sedimentation patterns: higher sediment concentrations enhance MP transport, and turbidity currents with finer sediments transported MPs over greater distances, highlighting the importance of sediment characteristics to predict MP distribution by such flows.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!