Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate the PR to RR interval ratio (PR/RR, heart rate-adjusted PR) as a prognostic marker for long-term ventricular arrhythmias and cardiac death in patients with implantable cardioverter defibrillator (ICDs) and cardiac resynchronization therapy with defibrillators (CRT-D).
Methods: We retrospectively analyzed data from 428 patients who had an ICD/CRT-D equipped with home monitoring. Baseline PR and RR interval data prior to ICD/CRT-D implantation were collected from standard 12-lead electrocardiograph, and the PR/RR was calculated. The primary endpoint was appropriate ICD/CRT-D treatment of ventricular arrhythmias (VAs), and the secondary endpoint was cardiac death.
Results: During a mean follow-up period of 38.8 ± 10.6 months, 197 patients (46%) experienced VAs, and 47 patients (11%) experienced cardiac death. The overall PR interval was 160 ± 40 ms, and the RR interval was 866 ± 124 ms. Based on the receiver operating characteristic curve, a cut-off value of 18.5% for the PR/RR was identified to predict VAs. A PR/RR ≥ 18.5% was associated with an increased risk of VAs [hazard ratio (HR) = 2.243, 95% confidence interval (CI) = 1.665-3.022, < 0.001) and cardiac death (HR = 2.358, 95%CI = 1.240-4.483, = 0.009) in an unadjusted analysis. After adjustment in a multivariate Cox model, the relationship remained significant among PR/RR ≥ 18.5%, VAs (HR = 2.230, 95%CI = 1.555-2.825, < 0.001) and cardiac death (HR = 2.105, 95%CI = 1.101-4.025, = 0.024.
Conclusions: A PR/RR ≥ 18.5% at baseline can serve as a predictor of future VAs and cardiac death in ICD/CRT-D recipients.