A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The transfer characteristics of heavy metals in electronic cigarette liquid. | LitMetric

The transfer characteristics of heavy metals in electronic cigarette liquid.

Environ Res

Department of Environmental Engineering, Pukyong National University, 45 Yongso-ro, Nam-gu, Busan, 48513, Republic of Korea. Electronic address:

Published: July 2019

In this research, the concentrations of six heavy metals (Zn, Pb, Ni, Fe, Cd, and Cr) in electronic cigarette (EC) solutions were determined to assess their association with EC use patterns. To this end, their contents were analyzed under three conditions: (1) ECL I: EC liquid was directly taken from EC liquid bottles as purchased from retail, (2) ECL II: EC liquid simply stored in the EC clearomizer for a certain period was collected without any puffing, and (3) ECL III: EC liquid remaining in the EC clearomizer after puffing. Each of all three types of electronic cigarette liquid (ECL) samples selected in this study was analyzed after being stored for up to seven days (at elapsed intervals of 1, 3, and 7 days). Zn and Pb were detected in all types of samples while Cd was all below method detection limit (MDL). Fe, Ni, and Cr were generally below MDL in ECL I, while it was not the case for ECL II and III samples. Especially, Zn, Pb, and Ni levels increased significantly with the use of EC. If the consumption of EC causes alterations in elemental content, such changes can be assessed in terms of ratio values such as "after/before use". The maximum ratio values for each target, when assessed using ECL III samples, were seen in the following order: 463 (Zn) > 315 (Ni) > 131 (Fe) > 47.9 (Cr) > 36.0 (Pb). As such, EC use is clearly demonstrated as the transfer route of heavy metals.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.envres.2019.04.025DOI Listing

Publication Analysis

Top Keywords

heavy metals
12
electronic cigarette
12
ecl iii
12
metals electronic
8
cigarette liquid
8
ecl liquid
8
iii samples
8
ratio values
8
ecl
7
liquid
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!