Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report.

J Prosthet Dent

Associate Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea. Electronic address:

Published: January 2020

A microlocking implant prosthetic system has recently been developed to address the limitations of conventional screw- and cement-retained implant-supported fixed dental prostheses. This prosthesis system consists of a precision-machined abutment and an attachment that includes zirconia balls and a nickel-titanium spring, thus providing retrievability and constant retention of the prosthesis. In addition, screw-related complications are avoided because there is no retention screw. The occlusal access hole is of a smaller diameter than that of conventional screw-retained prostheses, which is beneficial for esthetics and occlusion. It also prevents common complications of cement-retained prostheses because residual cement around the prosthesis can be removed extraorally. This article presents a clinical treatment with this new prosthetic system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2018.11.021DOI Listing

Publication Analysis

Top Keywords

prosthetic system
12
implant-supported fixed
8
fixed dental
8
microlocking implant
8
implant prosthetic
8
prosthesis
4
dental prosthesis
4
prosthesis microlocking
4
system
4
system clinical
4

Similar Publications

The radiotracer [F]JK-PSMA-7, a prostate cancer imaging agent for positron emission tomography (PET), was previously synthesized by indirect radiofluorination using an F-labeled active ester as a prosthetic group, which had to be isolated and purified before it could be linked to the pharmacologically active Lys-urea-Glu motif. Although this procedure could be automated on two-reactor modules like the GE TRACERLab FX2N (FXN) to afford the tracer in modest radiochemical yields (RCY) of 18-25%, it is unsuitable for cassette-based systems with a single reactor. To simplify implementation on an automated synthesis module, the radiosynthesis of [F]JK-PSMA-7 was devised as a one-pot, two-step reaction.

View Article and Find Full Text PDF

: Tactile gnosis derives from the interplay between the hand's tactile input and the memory systems of the brain. It is the prerequisite for complex hand functions. Impaired sensation leads to profound disability.

View Article and Find Full Text PDF

The study aimed to validate the diagnostic system proposed by the Standardized Tool for the Assessment of Bruxism (STAB) by correlating the results obtained based on questionnaire and non-instrumental and instrumental tools. The study had three stages (questionnaire, clinical examination, and electromyographic study). The subjects completed a questionnaire and clinical exam.

View Article and Find Full Text PDF

Introduction: Using digital technology, respectively the use of intraoral scanners has increased exponentially in recent years. Intraoral scanners have gained traction and widespread use in the field of dental prosthetics and orthodontics. While the use of these digital devices enables the detection of visible areas of error in order to allow clinicians to correct those areas immediately without a need of restarting the entire process from the beginning as it should be done in the conventional method and subsequent procedures.

View Article and Find Full Text PDF

A low-cost transhumeral prosthesis operated via an ML-assisted EEG-head gesture control system.

J Neural Eng

January 2025

Department of Electrical and Computer Engineering, Stony Brook University, 211 Light Engineering, Stony Brook University, Stony Brook, NY 11794, Stony Brook, New York, 11794, UNITED STATES.

Objective Key challenges in upper limb prosthetics include a lack of effective control systems, the often invasive surgical requirements of brain-controlled limbs, and prohibitive costs. As a result, disuse rates remain high despite potential for increased quality of life. To address these concerns, this project developed a low cost, noninvasive transhumeral neuroprosthesis-operated via a combination of electroencephalography (EEG) signals and head gestures.