Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Although an association between body weight mismatch and impaired graft function has been reported, few histologic studies have evaluated this issue, especially using electric microscopic analysis. During routine observations, we have noted a thin glomerular basement membrane (GBM) in the 1-hour biopsy specimen in cases with an overweight recipient and a lightweight donor. Therefore, we hypothesized that donor-recipient body weight mismatch affects the GBM thickness in the 1-hour biopsy specimen. The aim of the present study was to clarify the effect of donor-recipient body weight mismatch on the GBM thickness of the 1-hour biopsy specimen measured using electron microscopy.
Methods: We used an electron microscope to measure the GBM thickness of specimens at 1-hour post-transplantation (n = 24) and at 1 year post-transplantation (n = 17). The GBM thickness of cases with donor-recipient body weight mismatch was compared with those without mismatch. In accordance with a previous study, we defined a donor/recipient body weight ratio of less than 0.9 as donor-recipient body weight mismatch and a ratio of more than 0.9 as no mismatch.
Results: At 1-hour post-transplantation, the mean GBM was significantly thinner in the mismatch group than in the nonmismatch group. However, at 1-year post-transplantation, the mean GBM thickness did not significantly differ between the 2 groups.
Conclusions: The GBM thickness at 1-hour post-transplantation is thinner in cases with donor-recipient body weight mismatch than in cases without mismatch. This implies that donor-recipient body weight mismatch may have to be considered when assessing donor-derived thin GBM disease using the 1-hour biopsy specimen.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.transproceed.2019.01.144 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!