A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Addition of Optimized Bovine Serum Albumin Level in a High-Throughput Caco-2 Assay Enabled Accurate Permeability Assessment for Lipophilic Compounds. | LitMetric

The Caco-2 permeability assay is a well-accepted in vitro model to evaluate compounds' potential for oral absorption at early discovery. However, for many lipophilic compounds, no meaningful Caco-2 data could be generated due to their low solubility in assay buffer and/or poor recovery from the assay. In our previous study, we reported an organic catch approach to improve compound recovery. To further reduce compound loss and increase solubility in aqueous buffer, we explored the addition of bovine serum albumin (BSA). However, in contrast to the commonly used BSA level at 4%, a lower level of BSA was selected in an effort to minimize the potential risk of missing the identification of efflux substrates, and to avoid the extensive sample cleanup needed for 4% BSA. Through a systematic evaluation, it was found that 0.5% BSA was effective in enhancing compound solubility and reducing nonspecific binding, which allowed reliable assessment of the permeability and efflux potential for lipophilic compounds. Also, with an optimized sample handling process, no extra sample cleanup was required before liquid chromatography-mass spectrometry (LC-MS) analysis. The implementation of this assay has enabled accurate permeability assessment for compounds that had poor solubility and/or poor mass balance under the non-BSA assay conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1177/2472555219848483DOI Listing

Publication Analysis

Top Keywords

lipophilic compounds
12
bovine serum
8
serum albumin
8
assay enabled
8
enabled accurate
8
accurate permeability
8
permeability assessment
8
and/or poor
8
sample cleanup
8
assay
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!