Clinical substantiation of the sparing and less invasive implant prosthetics of the edentulous lower jaw method.

Stomatologija

Department of Orthopedic Dentistry and Materials Science with the course of orthodontics, I.P. Pavlov First State Medical University, Leo Tolstoy st. 6-8, St. Petersburg, Russia.

Published: October 2019

Objective: Proof of the effective implant prosthetics treatment of patients with the edentulous lower jaw by minimally invasive method.

Materials And Methods: As a sample of clinical research, 68 senior patients (30 men and 38 women) were diagnosed with edentulous lower jaws. The methods of the study included estimating the implant retention by frequency-resonance analysis of Osstell ISQ, the degree of retention and stabilization of the tissue supported and implant-supported dentures (author's method: patent for invention No. 2640375 of 28.12.2017) and a sociologic questionnaire "Profile of the influence of dental health OHIP-14".

Results: For the first time strength indicators of the retention and stabilization degree of implant-retained mandibular overdentures with attachment to one and two implants were determined. A linear relationship was shown between the degree of fixation of the prosthesis and the change in the quality of life (a statistically significant correlation was p=0.022, r=0.52 in the first group and p=0.0015; r=0.75 in the second group). The implants stability during the year increased in the first group in 2.57±1.59%, and in the second group in 2.08±1.40%. After a year using implant-retained mandibular overdentures, the life quality level concerning dental health in patients from the first and second groups remained the same (there were no statistically significant differences, p1-2=0.8392).

Conclusions: The performed survey of prosthetic treatment patients with the edentulous lower jaw showed the effect use of a sparing method of implantation prosthetics. The fixation quality achieved with a single support-retaining implant was sufficient to improve the functional and comfortable using of the lower jaw prosthesis. It was found that the stability of implants statistically did not significantly depend on the number of used implants (p>0.05).

Download full-text PDF

Source

Publication Analysis

Top Keywords

edentulous lower
16
lower jaw
16
implant prosthetics
8
treatment patients
8
patients edentulous
8
retention stabilization
8
dental health
8
implant-retained mandibular
8
mandibular overdentures
8
second group
8

Similar Publications

Aim: The current study aimed to assess the oropharyngeal space using cone-beam computed tomography (CBCT) and its effect on airway volume both before and after denture placement.

Materials And Methods: For this investigation, a total of 15 individuals with fully edentulous upper and lower ridges, ranging in age from 40 to 70, were taken into consideration. A recording of the pulmonary function test was made both prior to and following full denture recovery.

View Article and Find Full Text PDF

Light-polymerizing reline materials offer improved chairside workability compared to conventional auto-polymerizing reline materials, addressing the partial denture (RPD) incompatibility caused by residual ridge resorption owing to long-term use. This study evaluates the fitting accuracy of relined materials by combining conventional fitting tests with three-dimensional (3D) measurements for detailed analysis. Light-polymerizing reline material (HikariLiner, Tokuyama, Tokyo, Japan, LP) and auto-polymerizing material (Rebase III, Tokuyama, AP) were used.

View Article and Find Full Text PDF

: All-cause mortality consisting of several heterogeneous subgroups does not have a well-defined set of risk factors. Despite the well-described role of oral hygiene on mortality, the association between the condition of the existing dentition and mortality remains unclear. Therefore, we embarked on the current study to assess the association of oral hygiene self-care (OHS) with all-cause mortality.

View Article and Find Full Text PDF

Purpose: This pilot study evaluated and compared histomorphometric and immunohistochemical characteristics of peri-implant bone tissue after implant site preparation using piezoelectric tips versus conventional drills.

Material And Methods: Six patients with bilateral partial edentulism underwent a splitmouth protocol. Twelve alveolar ridges were randomized into six control implant sites prepared using conventional drills (Drill Group); and six test implant sites prepared using piezoelectric implant inserts (Piezo Group).

View Article and Find Full Text PDF

This study examines whether age-related cognitive decline varies by race/ethnicity and how edentulism moderates these effects. Data from the Health and Retirement Study (2006-2020), including 23,669 respondents aged 51 and above across 189,352 person-wave observations were analyzed. Of all respondents, 13.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?