A piezoelectric deformable X-ray mirror for phase compensation based on global optimization.

J Synchrotron Radiat

Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Zhangheng Road 239, Pudong District, Shanghai 201204, People's Republic of China.

Published: May 2019

As a strong tool for the study of nanoscience, the synchrotron hard X-ray nanoprobe technique enables researchers to investigate complex samples with many advantages, such as in situ setup, high sensitivity and the integration of various experimental methods. In recent years, an important goal has been to push the focusing spot size to the diffraction limit of ∼10 nm. The multilayer-based Kirkpatrick-Baez (KB) mirror system is one of the most important methods used to achieve this goal. This method was chosen by the nanoprobe beamline of the Phase-II project at the Shanghai Synchrotron Radiation Facility. To overcome the limitations of current polishing technologies, the use of an additional phase compensator was necessary to decrease the wavefront distortions. In this experiment, a prototype phase compensator has been created to show how to obtain precise wavefront compensation. With the use of finite-element analysis and Fizeau interferometer measurements, some important factors such as the piezoresponse, different actuator distributions, stability and hysteresis were investigated. A global optimization method based on the measured piezoresponse has also been developed. This method overcame the limitations of the previous local algorithm related to the adjustment of every single actuator for compact piezoelectric layouts. The mirror figure can approach a target figure after several iterations. The figure difference can be reduced to several nanometres, which is far better than the mirror figure errors. The prototype was also used to successfully compensate for the real wavefront errors from upstream and for its own figure errors, measured using the speckle scanning technique. The residual figure error was reduced to a root-mean-square value of 0.7 nm.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S1600577519003047DOI Listing

Publication Analysis

Top Keywords

global optimization
8
phase compensator
8
mirror figure
8
figure errors
8
figure
6
piezoelectric deformable
4
deformable x-ray
4
mirror
4
x-ray mirror
4
mirror phase
4

Similar Publications

Empathy is multifaceted, involving sharing and understanding the emotional and mental states of others. This study investigated the factor structure of the English-language version of the Empathy Quotient for Children (EQ-C; Auyeung et al., 2009), an empathy measure previously well-validated only as a global scale.

View Article and Find Full Text PDF

Oocyte maturation defect in women undergoing IVF: contributing factors and effects on mature sibling oocyte outcomes.

J Assist Reprod Genet

January 2025

IVIRMA Global Research Alliance, RMA New Jersey, 140 Allen, Basking Ridge, NJ, 07920, USA.

Purpose: This study aimed to identify demographic and clinical factors associated with low maturation rates and to investigate if the rate of immature oocytes impacts the outcomes of mature sibling oocytes.

Methods: Women undergoing their first IVF-ICSI cycle between 2018 and 2022 at a fertility clinic were included. Cycles were classified into five groups according to the proportion of Metaphase II stage oocytes (MII): Null (0% MII, n = 46), Poor (1-25% MII, n = 44), Low (26-50% MII, n = 453), Acceptable (51-75% MII, n = 1641), and Optimal (76-100% MII, n = 2642).

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

University of Oxford, Oxford, United Kingdom.

Background: Alzheimer's disease (AD) impacts over 50 million individuals and imposes a substantial burden on patients, caregivers, and society at large. Recent research suggests that AD is a continuum comprising preclinical, prodromal, and dementia stages, with underlying pathology manifesting well before symptoms appear. Early and accurate diagnosis is therefore crucial for optimal clinical outcomes; yet current diagnostic methods, such as neuroimaging and cerebrospinal fluid lumbar puncture, are expensive and invasive.

View Article and Find Full Text PDF

Biomarkers.

Alzheimers Dement

December 2024

IXICO, London, Greater London, UK.

Background: Use of the supratentorial white matter (sWM) as a reference region for amyloid PET, alone or in a composite, can facilitate the detection of subtle changes in amyloid load (Wong et al., 2010; Landau et al., 2015).

View Article and Find Full Text PDF

Background: A key characteristic of Alzheimer's disease (AD) is cerebral aggregation of tau. These aggregates can be quantified and localized with positron emission tomography (PET), which improves the diagnostic and prognostic work-up of AD. However, tau-PET is expensive and not available in clinical settings globally.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!