Early onset prosthetic valve stenosis is an uncommon complication after valve replacement surgery and is often caused by thrombus formation. Frequently it can be diagnosed by echocardiography and managed with optimizing anticoagulation and/or thrombolysis. We review a unique case of early bi-leaflet mechanical heart valve (BMHV) dysfunction where the patient rapidly progressed to cardiogenic shock requiring emergent re-do mitral valve surgery. Intraoperatively, the valve leaflets were found to be almost completely immobile secondary to thrombus formation directly on the hinges of the valve. This case demonstrates how the leaflet orientation of a BMHV affects transmitral flow and fluid dynamics. Furthermore, we also discuss left atrial vortex formation in the setting of atrial fibrillation, kinetic energy transfer through an anatomically implanted mechanical mitral valve, and their roles in contributing to early prosthetic valve thrombosis despite adequate anticoagulation.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2019.03.016DOI Listing

Publication Analysis

Top Keywords

prosthetic valve
12
mitral valve
12
valve
10
early prosthetic
8
cardiogenic shock
8
valve replacement
8
thrombus formation
8
early
4
valve malfunction
4
malfunction leading
4

Similar Publications

Background: Transcatheter closure of percutaneous paravalvular leak (PVL) is a technically challenging procedure, especially after surgical mechanical valve replacements (SMVR), as the risk of interference with the prosthetic valve discs and the complex interventional techniques required for mitral PVL closure. Our study was designed to review the results with transcatheter closure of PVL after SMVR.

Methods: From January 2018 through December 2023, a total of 64 patients with PVL after SMVR underwent transcatheter closure with the help of preoperative 3-dimensional printing model and simulator for image evaluation.

View Article and Find Full Text PDF

Analysis of the haemodynamic changes caused by surgical and transcatheter aortic valve replacements by means fluid-structure interaction simulations.

Comput Biol Med

January 2025

UCL Mechanical Engineering, University College London, UK; Ri.MED Foundation, Palermo, Italy; University of Palermo, Department of Engineering, Palermo, Italy. Electronic address:

Aortic valve replacements, both surgical and transcatheter, are nowadays widely employed treatments. Although clinically effective, these procedures are correlated with potentially severe clinical complications which can be associated with the non-physiological haemodynamics that they establish. In this work, the fluid dynamics changes produced by surgical and transcatheter aortic valve replacements are analysed and compared with an ideal healthy native valve configuration, employing advanced fluid-structure interaction (FSI) simulations.

View Article and Find Full Text PDF

Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.

View Article and Find Full Text PDF

The spleen plays a crucial role in filtering aging blood cells and defending against encapsulated microorganisms. While not essential for survival, splenic dysfunction can lead to severe complications, including organ failure, infection, and death. This case study examines a rare presentation of drug-induced splenic septic thrombophlebitis secondary to pancreatitis caused by an adverse reaction to ceftriaxone.

View Article and Find Full Text PDF

Aortic valve leaflet assessment to inform novel bioinspired materials: Understanding the impact of collagen fibres on the tissue's mechanical behaviour.

J Mech Behav Biomed Mater

December 2024

Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, 2, Dublin, Ireland; Discipline of Mechanical, Manufacturing, and Biomedical Engineering, School of Engineering, Trinity College Dublin, 2, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Trinity College Dublin, Ireland. Electronic address:

Aortic stenosis is a prevalent disease that is treated with either mechanical or bioprosthetic valve replacement devices. However, these implants can experience problems with either functionality in the case of mechanical valves or long-term durability in the case of bioprosthetic valves. To enhance next generation prosthetic valves, such as biomimetic polymeric valves, an improved understanding of the native aortic valve leaflet structure and mechanical response is required to provide much needed benchmarks for future device development.

View Article and Find Full Text PDF