Background: Myopia is a common visual disorder with increasing prevalence. Halting progression of myopia is critical, as high myopia can be complicated by a number of vision-compromising conditions.
Methods: Literature search was conducted in the following databases: Medical Literature Analysis and Retrieval System Online (MEDLINE), Excerpta Medica dataBASE (EMBASE), Cochrane Database of Systematic Reviews (CDSR), Database of Abstracts of Reviews of Effects (DARE) and Centre for Reviews and Dissemination (CRD) Health Technology Assessment (HTA) database. Systematic reviews and meta-analyses investigating the efficacy and safety of multiple myopia interventions vs control conditions, were considered. Methodological quality and quality of evidence of eligible studies were assessed using the ROBIS tool and GRADE rating. The degree of overlapping of index publications in the eligible reviews was calculated with the corrected covered area (CCA).
Results: Forty-four unique primary studies contained in 18 eligible reviews and involving 6400 children were included in the analysis. CCA was estimated as 6.2% and thus considered moderate. Results demonstrated the superior efficacy of atropine eyedrops; 1% atropine vs placebo (change in refraction: -0.78D, [- 1.30 to - 0.25] in 1 year), 0.025 to 0.05% atropine vs control (change in refraction: -0.51D, [- 0.60 to - 0.41] in 1 year), 0.01% atropine vs control (change in refraction: -0.50D, [- 0.76 to - 0.24] in 1 year). Atropine was followed by orthokeratology (axial elongation: - 0.19 mm, [- 0.21 to - 0.16] in 1 year) and novel multifocal soft contact lenses (change in refraction: -0.15D, [- 0.27 to - 0.03] in 1 year). As regards adverse events, 1% atropine induced blurred near vision (odds ratio [OR] 9.47, [1.17 to 76.78]) and hypersensitivity reactions (OR 8.91, [1.04 to 76.03]).
Conclusions: Existing evidence has failed to convince doctors to uniformly embrace treatments for myopic progression control, possibly due to existence of some heterogeneity, reporting of side effects and lack of long-term follow-up. Research geared towards efficient interventions is still necessary.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6506938 | PMC |
http://dx.doi.org/10.1186/s12886-019-1112-3 | DOI Listing |
Sci Rep
December 2024
College of Education, Department of Physics, Misan University, Amarah, Iraq.
This study introduces a high-performance 4-channel Metal-Insulator-Metal (MIM) diplexer, employing silver and Teflon, optimized for advanced photonic applications. The proposed diplexer, configured with two novel band-pass filters (BPFs), operates across four distinct wavelength bands (843 nm, 1090 nm, 1452 nm, 1675 nm) by precisely manipulating the passband dimensions. Utilizing Finite-Difference Time-Domain (FDTD) simulations, the designed diplexer achieves exceptional sensitivity values of 3500 nm/RIU, 4250 nm/RIU, 3375 nm/RIU, and 4003 nm/RIU, along with high figures of merit (FOM) ranging from 113.
View Article and Find Full Text PDFEnviron Sci Technol
December 2024
Climate and Environmental Physics, Physics Institute, and Oeschger Centre for Climate Change Research, University of Bern, Sidlerstrasse 5, Bern 3012, Switzerland.
This study presents the integration of the single-particle extinction and scattering (SPES) method in a continuous flow analysis (CFA) setup. Continuous measurements with the instrument allow for the characterization of water-insoluble particles in ice cores at high resolution with a minimized risk of contamination. The SPES method can be used to investigate particles smaller than 1 μm, which previously could not be detected by instruments typically used in CFA.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Ophthalmology, Jinshan Hospital of Fudan University, 1508 Longhang Road, Jinshan District, Shanghai, China.
To observe the structural changes of retina and choroid in patients with different degrees of myopia. We recruited 219 subjects with different degrees of myopia for best corrected visual acuity, computer refraction, intraocular pressure, axial length (AL), optical coherence tomography (OCT) imaging, and other examinations. Central macular retinal thickness (CRT), subfoveal choroidal thickness (SFCT), nasal retinal thickness (NRT), temporal retinal thickness (TRT), nasal choroidal thickness (NCT) and temporal choroidal thickness (TCT) were measured by optical coherence tomography.
View Article and Find Full Text PDFVision (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, LV-1004 Riga, Latvia.
Virtual reality (VR) can challenge the visual system, leading to temporary oculomotor changes, though the degree of change varies among individuals. While the vergence and accommodation system plays a crucial role in VR perception, it remains unclear whether individuals whose visual functions fall outside clinical norms experience larger changes. Thus, our study aimed to investigate whether changes in vergence and accommodation responses following VR gameplay differ between individuals with and without non-strabismic binocular and accommodative disorders.
View Article and Find Full Text PDFIndian J Ophthalmol
December 2024
Department of Ophthalmology, Swiss Vision Eye Group, Istanbul, Turkey.
Objectives: To demonstrate corneal remodeling after corneal allograft intrastromal ring segment (CAIRS) with an anterior-segment optical coherence tomography (AS-OCT).
Design: A prospective observational single-center study.
Methods: This observational study included keratoconus patients who underwent CAIRS implantation into a stromal tunnel.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!