A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A prospective RCT comparing combined chromoendoscopy with water exchange (CWE) vs water exchange (WE) vs air insufflation (AI) in adenoma detection in screening colonoscopy. | LitMetric

Background: A low adenoma detection rate (ADR) increases risks of interval cancers (ICs). Proximal colon flat polyps, e.g. serrated lesions (SLs), are difficult to find. Missed proximal colon flat lesions likely contribute to IC.

Aims: We compared chromoendoscopy with water exchange (CWE), water exchange (WE) and air insufflation (AI) in detecting adenomas in screening colonoscopy.

Methods: After split-dose preparation, 480 veterans were randomized to AI, WE and CWE.

Results: Primary outcome of proximal ADR (55.6% vs 53.4% vs 52.2%, respectively) were similar in all groups. Adenoma per colonoscopy (APC) and adenoma per positive colonoscopy (APPC) were comparable. Detection rate of proximal colon SLs was significantly higher for CWE and WE than AI (26.3%, 23.6% and 11.3%, respectively,  = 0.002). Limitations: single operator; SLs only surrogate markers of but not IC.

Conclusions: When an endoscopist achieves high-quality AI examinations with overall ADR twice (61.6%) the recommended standard (30%), use of WE and CWE does not produce further improvement in proximal or overall ADR. Comparable APC and APPC confirm equivalent withdrawal inspection techniques. WE alone is sufficient to significantly improve detection of proximal SLs. The impact of increased detection of proximal SLs by WE on prevention of IC deserves to be studied. This study is registered at ClinicalTrial.gov (NCT#01607255).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6488805PMC
http://dx.doi.org/10.1177/2050640619832196DOI Listing

Publication Analysis

Top Keywords

water exchange
16
proximal colon
12
chromoendoscopy water
8
exchange cwe
8
cwe water
8
exchange air
8
air insufflation
8
adenoma detection
8
detection rate
8
colon flat
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!