A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants. | LitMetric

Factors Influencing Resonance Frequency Analysis (RFA) Measurements and 5-Year Survival of Neoss Dental Implants.

Int J Dent

Department of Oral & Maxillofacial Surgery, Institute of Odontology, Sahlgrenska Academy, University of Gothenburg, P.O. Box 450, 405 30 Gothenburg, Sweden.

Published: April 2019

Background: Diagnostic instruments based on resonance frequency analysis (RFA) can be utilised to assess dental implant stability during treatment and follow-up.

Aim: The aim of the present study was to investigate the influence of patient- and implant-related factors on implant stability and the 5-year implant survival. In addition, the influence of stability (ISQ value) at placement and abutment connection on implant survival was evaluated.

Materials And Methods: RFA measurements from a total of 334 consecutive patients with 745 dental implants (Neoss Ltd., Harrogate, UK) were retrospectively analysed after at least 5 years in function. Statistics were used to evaluate the influence of the different variables on implant stability and implant survival. Odds ratio calculations were performed to compare the risk for implant failure using 60, 65, 70, and 75 ISQ as threshold levels at placement and loading.

Results: A total of 20 implant failures in 14 patients were noted during the 5 years of follow-up, giving an overall cumulative survival rate (CSR) of 97.3% at the implant level and 95.8% at the patient level. Gender, jaw, position, bone quality, and implant diameter had an influence on implant stability at placement. Jaw, bone quality, and implant diameter had an influence on stability after 3-4 months of healing. More failures were observed in full than in partial rehabilitations. Age, gender, jaw, position, bone quantity, bone quality, implant diameter, and implant length had no influence on implant survival. Implants with ISQ values below the threshold levels showed lower survival rates compared to implants with values above these levels.

Conclusions: The present study showed a significantly higher risk for implant failure, showing an ISQ value below 70 and 75 at placement or after 3-4 months of healing. The results indicate that RFA measurements can be used to identify implants with increased risk for failure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6466959PMC
http://dx.doi.org/10.1155/2019/3209872DOI Listing

Publication Analysis

Top Keywords

implant
16
implant stability
16
implant survival
16
rfa measurements
12
bone quality
12
quality implant
12
implant diameter
12
resonance frequency
8
frequency analysis
8
analysis rfa
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!