A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement error in μCT-based three-dimensional geometric morphometrics introduced by surface generation and landmark data acquisition. | LitMetric

Computed-tomography-derived (CT-derived) polymesh surfaces are widely used in geometric morphometric studies. This approach is inevitably associated with decisions on scanning parameters, resolution, and segmentation strategies. Although the underlying processing steps have been shown to potentially contribute artefactual variance to three-dimensional landmark coordinates, their effects on measurement error have rarely been assessed systematically in CT-based geometric morphometric studies. The present study systematically assessed artefactual variance in landmark data introduced by the use of different voxel sizes, segmentation strategies, surface simplification degrees, and by inter- and intra-observer differences, and compared their magnitude to true biological variation. Multiple CT-derived surface variants of the anuran (Amphibia: Anura) pectoral girdle were generated by systematic changes in the factors that potentially influence the surface geometries. Twenty-four landmarks were repeatedly acquired by different observers. The contribution of all factors to the total variance in the landmark data was assessed using random-factor nested permanovas. Selected sets of Euclidean distances between landmark sets served further to compare the variance among factor levels. Landmark precision was assessed by landmark standard deviation and compared among observers and days. Results showed that all factors, except for voxel size, significantly contributed to measurement error in at least some of the analyses performed. In total, 6.75% of the variance in landmark data that mimicked a realistic biological study was caused by measurement error. In this landmark dataset, intra-observer error was the major source of artefactual variance followed by inter-observer error; the factor segmentation contributed < 1% and slight surface simplification had no significant effect. Inter-observer error clearly exceeded intra-observer error in a different landmark dataset acquired by six partly inexperienced observers. The results suggest that intra-observer error can potentially be reduced by including a training period prior to the actual landmark acquisition task and by acquiring landmarks in as few sessions as possible. Additionally, the application of moderate and careful surface simplification and, potentially, also the use of case-specific optimal combinations of automatic local thresholding algorithms and parameters for segmentation can help reduce intra-observer error. If landmark data are to be acquired by several observers, it is important to ensure that all observers are consistent in landmark identification. Despite the significant amount of artefactual variance, we have shown that landmark data acquired from microCT-derived surfaces are precise enough to study the shape of anuran pectoral girdles. Yet, a systematic assessment of measurement error is advisable for all geometric morphometric studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6637444PMC
http://dx.doi.org/10.1111/joa.12999DOI Listing

Publication Analysis

Top Keywords

landmark data
24
measurement error
20
artefactual variance
16
variance landmark
16
intra-observer error
16
landmark
14
geometric morphometric
12
morphometric studies
12
surface simplification
12
error landmark
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!