Purpose: To compare functional outcomes and magnetic resonance image (MRI) tendon integrity following either the suture bridge or the knotless cinch-bridge technique used for arthroscopic double-layer rotator cuff repair.

Methods: 37 prospectively enrolled patients (46-76 years), who were treated with arthroscopic double-layer rotator cuff repair (group 1: suture bridge n = 20, group 2: cinch bridge n = 17) were clinically and radiographically assessed before and at an average of 24.0 ± 4.7 months after the procedure. Shoulder function was evaluated by the constant score (CS), range of motion, and various patient-related scores. Repaired tendon integrity was evaluated by MRI. Peri- and postoperative complications were recorded.

Results: All functional and patient-related scores significantly improved from pre- to postoperative. Significantly better postoperative CS (P = 0.037), flexion (P < 0.001), and abduction (P = 0.009) were detected after arthroscopic cinch compared to suture-bridge repair. The mean CS improvements from baseline to follow-up were not significantly different between the groups (n.s.). Patient-related scores did not show any statistical significant differences. The MRI healing rate following arthroscopic double-layer repair with the suture- and cinch-bridge technique was 95% and 94%, respectively. Fatty infiltration regarding the supraspinatus and infraspinatus increased in 55% and 35% (group 1) and in 53% and 48% (group 2), respectively. Muscle hypotrophy remained stable in all patients. Overall, 92% of the patients were very satisfied or satisfied with the procedure. No complications were detected.

Conclusions: Arthroscopic knotless double-layer rotator cuff repair with the cinch-bridge technique showed higher CS, forward flexion, and abduction values, as well as similar patient-related short-term outcome and MRI integrity compared to the suture-bridge technique. These results highlight the potential importance of less tendon strangulation for better clinical short-term outcome.

Level Of Evidence: Level II, prospective comparative study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-019-05519-xDOI Listing

Publication Analysis

Top Keywords

rotator cuff
12
knotless cinch-bridge
8
cinch-bridge technique
8
tendon integrity
8
suture bridge
8
arthroscopic double-layer
8
double-layer rotator
8
patient-related scores
8
technique delaminated
4
delaminated rotator
4

Similar Publications

Background: Sports-related injuries remain a significant problem for collegiate baseball players. Although some studies reported the epidemiology of sports-related injuries among collegiate baseball players, the latest information on sport-related injuries should be provided.

Purpose: To examine the current trends of sports-related injuries among collegiate baseball players in the Pacific 12 (PAC-12) Conference.

View Article and Find Full Text PDF

Failure of rotator cuff repairs contributes to decreased patient satisfaction and quality of life. Biologic enhancement of repairs represents a novel augmentation strategy attempting to reproduce native healing while concomitantly potentially decreasing the existing high failure rates associated with rotator cuff repairs. Scaffolds placed on top of the rotator cuff have been widely studied, yet no recreation of the native enthesis is achieved via this augmentation strategy.

View Article and Find Full Text PDF

The Mason-Loop for Single-Row Full-Thickness Rotator Cuff Repair.

Arthrosc Tech

December 2024

Ramsay Général de Santé, Cliques des Maussins, Paris, France.

Rotator cuff injuries are common and can lead to pain and functional limitation of the shoulder, sometimes requiring surgical procedure. We describe a surgical approach combining the modified Mason-Allen and lasso-loop techniques for the repair of rotator cuff injuries. This hybrid approach brings the 2 advantages of each suture: the compression provided by the loop and the large quantity of tendons caught by the Mason-Allen in a single repair row.

View Article and Find Full Text PDF

Rotator cuff tears are a common cause of shoulder pain and dysfunction. Recent and historical reports suggest that a sizable percentage of patients may experience a retear of the rotator cuff despite surgical intervention. Multiple biological and mechanical factors can influence outcomes after rotator cuff surgery, including patient age, rotator cuff tear size, chronicity, and rotator cuff tissue quality.

View Article and Find Full Text PDF

Lower trapezius tendon transfer is a surgical procedure that has become increasingly popular in recent years. The biggest advantage of this method is that the pulling direction of the lower trapezius is the same as that of the infraspinatus. Thus, the transferred lower trapezius tendon can biomechanically mimic the functions of the posterior-superior rotator cuff.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!