Prosthetic mechanical valves are the elective choice in mitral valve (MV) replacement, because of their reliability and easiness of implantation. However, these prostheses can suffer from complications, the major one being prosthetic mitral valve thrombosis (PMVT). In these cases, transthoracic doppler echocardiogram (TDE) is the standard diagnostic workup for diagnosis of valve malfunction. The American Society of Echocardiography (ASE) indicates the possible TDE-derived indexes, which can help in identifying insurgence of MV replacement complications. Unfortunately, in some cases, it is not possible to detect PMVT based on these criteria. In these cases, we speak of Doppler silent thrombosis and only more accurate and invasive analyses, such as fluoroscopy, allow for a correct diagnosis. In this work, computational fluid dynamic models were implemented to simulate valve fluid dynamics in different clinical scenarios in order to improve the reliability of PMVT diagnosis based on TDE. In detail, seven mechanical valve configurations, associated to different potential thrombotic conditions (symmetric and asymmetric stenosis), were designed and tested using five pathologic transmitral velocity profile, extracted from real TDE images; to obtain the flow rate profiles, each TDE velocity profile was scaled to yield a mean flow rate (MFR) of 4, 5 and 6 L/min, respectively. As a result, 105 (7 × 5 × 3) synthetic cases, accounting for different velocity profiles, MFRs and valve configurations, were simulated. TDE-derived indexes were calculated according to the ASE guidelines that were extracted. Advanced statistical methods were applied to propose a new diagnostic algorithm for detecting PMVT. Our results showed that there isn't any significant difference between symmetric and asymmetric stenosis, probe location and flow rate waveform and confirmed that the single modality diagnostic is not able to predict thrombosis in a relevant number of cases, referable to mild and mild-severe stenosis cases. To overcome the problem, a novel multi-parametric discrete score based on the designed diagnostic algorithm was attained and tested; the percentage of stenosis (POS) was predicted with an accuracy rate of 90.5%. Even more interestingly, the error rate of 9.5% is related to four false positive cases corresponding to mild stenosis (POS = 15%) which were erroneously classified as mild-severe stenosis. No false negatives were obtained. Our results suggest that a reliable estimation must take into account the mean flow rate as well as the transmitral velocity profile in order to provide a correct diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2019.03.011DOI Listing

Publication Analysis

Top Keywords

flow rate
16
mitral valve
12
velocity profile
12
prosthetic mitral
8
cases
8
tde-derived indexes
8
correct diagnosis
8
valve configurations
8
symmetric asymmetric
8
asymmetric stenosis
8

Similar Publications

Reduction of glucose transporter 1 (GLUT1), even deletion, may results in cartilage fibrosis and osteoarthritis. This study aims to investigate the SUMOylation of GLUT1 in osteoarthritis through small ubiquitin-like modifier 1(SUMO1), and explore the role of SUMOylated GLUT1 in glycometabolism, proliferation and apoptosis in chondrocytes. Human chondrocytes were incubated with 10 ng/mL of IL-1β to mimic osteoarthritis in vitro.

View Article and Find Full Text PDF

Managerial factors affecting milking-abilities of Holstein cattle under intensive production system in Egypt.

Trop Anim Health Prod

January 2025

Department of Animal Production, Faculty of Agriculture, Menoufia University, Shibin Al Kawm, Egypt.

This article aims to explore milking-ability criteria of Holstein dairy cattle under intensive production system in Egypt and investigate some managerial factors that influence them in dairy farms. The data obtained from five herds belong to a commercial intensive production system farm, Egypt. Data included 3509 records.

View Article and Find Full Text PDF

Impeller radial gap is one of important parts within a blood pump, which may affect the hemodynamics and hemocompatibility. In this study, computational fluid dynamics method was performed to evaluate the impact of radial gap sizes. The volume of scalar shear stress decreased with radial gap sizes increasing.

View Article and Find Full Text PDF

Pediatric Brain Tumors in Western Kenya: Patient Outcomes and Healthcare Providers' Perspectives.

Pediatr Blood Cancer

January 2025

Academic Model Providing Access to Healthcare (AMPATH), Eldoret, Kenya.

Background: Pediatric brain tumors are understudied compared to other pediatric malignancies in low- and middle-income countries. Care delivery is inherently dependent on collaboration between multiple departments. This study aimed to present baseline data of pediatric neuro-oncology care in Western Kenya and illustrate barriers and facilitators of multidisciplinary care.

View Article and Find Full Text PDF

According to current guidelines, patients with heart valve disease should be followed by Heart Valve Clinics (HVCs). Regular quality analysis is a major prerequisite of an HVC's program, but few data have been reported so far. We retrospectively collected patients with isolated, native aortic valve stenosis who had been visited in our HVC at least once between 2021 and 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!