Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the accuracy of intraocular lens (IOL) power calculations using ray tracing software in patients who had undergone phototherapeutic keratectomy (PTK).
Methods: In this retrospective case series, 37 eyes of 22 patients (mean age: 69.4 years; range: 56 to 85 years) who underwent cataract surgery after PTK were reviewed. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using the following formulas: OKULIX (Tedics, Dortmund, Germany), PhacoOptics (IOL Innovations ApS, Aarhus, Denmark), Barrett True K No History (NH), and Camellin-Calossi. The PhacoOptics formula was used in three different ways: historical method (H), no history method (NH), and C-constant method (C). The median values of the arithmetic and absolute prediction errors among these six IOL calculation methods were compared.
Results: The median arithmetic errors (in diopters [D]) and percentages of eyes within ±0.50 D of the absolute errors were as follows: OKULIX (0.33, range: -2.20 to 2.50, 30.6%), PhacoOptics (H) (-0.12, range: -3.28 to 4.85, 22.2%), PhacoOptics (NH) (-0.25, range: -2.08 to 1.70, 48.4%), PhacoOptics (C) (0.04, range: -1.40 to 2.18, 48.5%), Barrett True K (NH) (-0.35, range: -1.90 to 1.89, 48.6%), and Camellin-Calossi (-0.19, range: -1.78 to 1.47, 59.5%).
Conclusions: The PhacoOptics, especially the C-constant method (C), and Camellin-Calossi formulas were good options for calculating IOL powers in eyes that underwent PTK. [J Refract Surg. 2019;35(5):310-316.].
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3928/1081597X-20190410-01 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!