A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the Accuracy of Newer Intraocular Lens Power Calculation Methods in Eyes That Underwent Previous Phototherapeutic Keratectomy. | LitMetric

Purpose: To evaluate the accuracy of intraocular lens (IOL) power calculations using ray tracing software in patients who had undergone phototherapeutic keratectomy (PTK).

Methods: In this retrospective case series, 37 eyes of 22 patients (mean age: 69.4 years; range: 56 to 85 years) who underwent cataract surgery after PTK were reviewed. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using the following formulas: OKULIX (Tedics, Dortmund, Germany), PhacoOptics (IOL Innovations ApS, Aarhus, Denmark), Barrett True K No History (NH), and Camellin-Calossi. The PhacoOptics formula was used in three different ways: historical method (H), no history method (NH), and C-constant method (C). The median values of the arithmetic and absolute prediction errors among these six IOL calculation methods were compared.

Results: The median arithmetic errors (in diopters [D]) and percentages of eyes within ±0.50 D of the absolute errors were as follows: OKULIX (0.33, range: -2.20 to 2.50, 30.6%), PhacoOptics (H) (-0.12, range: -3.28 to 4.85, 22.2%), PhacoOptics (NH) (-0.25, range: -2.08 to 1.70, 48.4%), PhacoOptics (C) (0.04, range: -1.40 to 2.18, 48.5%), Barrett True K (NH) (-0.35, range: -1.90 to 1.89, 48.6%), and Camellin-Calossi (-0.19, range: -1.78 to 1.47, 59.5%).

Conclusions: The PhacoOptics, especially the C-constant method (C), and Camellin-Calossi formulas were good options for calculating IOL powers in eyes that underwent PTK. [J Refract Surg. 2019;35(5):310-316.].

Download full-text PDF

Source
http://dx.doi.org/10.3928/1081597X-20190410-01DOI Listing

Publication Analysis

Top Keywords

intraocular lens
8
calculation methods
8
eyes underwent
8
phototherapeutic keratectomy
8
barrett true
8
c-constant method
8
range
7
phacooptics
6
comparison accuracy
4
accuracy newer
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!