Precis: In this retrospective case series of 85 eyes, 31.8% developed graft failure and graft survival was 50% at 3 years. The presence of an aqueous shunt has a significantly adverse effect on long-term graft survival.

Purpose: To report visual outcomes and complications of Descemet stripping endothelial keratoplasty (DSEK) in eyes with glaucoma drainage devices (GDD).

Materials And Methods: A retrospective chart review was conducted of 122 procedures of 85 eyes of 83 patients who underwent DSEK and had prior or concurrent GDD implantation. Mean follow-up was 36.5±31.4 months. Patients with postoperative follow-up of <3 months were excluded from analysis. Outcome measures examined included visual acuity, donor dislocation rate, intraocular pressure (IOP), and graft survival.

Results: The mean logMAR vision improved to 1.07 postoperatively from 1.43 preoperatively, with 61% of eyes experiencing improved visual acuity. Graft dislocation occurred in 27 (31.8%) eyes and required repeat injection of air in the anterior chamber. Primary graft failure occurred in 2 (2.4%) eyes, whereas secondary graft failure occurred in 27 (31.8%) of eyes, with an average time of 24.3 months for development. Estimated survival rates at 1, 2, and 3 years were 89%, 78%, and 50%, respectively. Escalation of IOP occurred in 21 (24.7%) eyes postoperatively, where 14 eyes underwent medical therapy and 7 eyes required surgical intervention/laser for IOP control.

Conclusions: DSEK after GDD is a viable alternative to treat endothelial dysfunction, with the majority of patients achieving visual improvement. However, aqueous shunt implantation has a significantly adverse effect on long-term graft survival and close follow-up is warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IJG.0000000000001272DOI Listing

Publication Analysis

Top Keywords

descemet stripping
8
stripping endothelial
8
endothelial keratoplasty
8
eyes glaucoma
8
glaucoma drainage
8
drainage devices
8
clinical outcomes
4
outcomes descemet
4
eyes
4
keratoplasty eyes
4

Similar Publications

4.5-Year Follow-up with a Novel Corneal Endothelial Prosthesis.

Klin Monbl Augenheilkd

January 2025

Ophthalmology, Amsterdam UMC, Amsterdam, Netherlands.

Background: Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain.

View Article and Find Full Text PDF

Fuchs Endothelial Corneal Dystrophy (FECD) is the most frequent indication for corneal transplantation, with Descemet membrane endothelial keratoplasty (DMEK), Descemet stripping automated endothelial keratoplasty (DSAEK), and penetrating keratoplasty (PK) being viable options. This retrospective study compared 10-year outcomes of these techniques in a large cohort of 2956 first-time keratoplasty eyes treated for FECD at a high-volume corneal transplant center in Germany. While DMEK and DSAEK provided faster visual recovery (median time to BSCVA ≥ 6/12 Snellen: DMEK 7.

View Article and Find Full Text PDF

Purpose: To evaluate Descemet membrane endothelial keratoplasty (DMEK) for failed endothelial keratoplasty (EK).

Methods: We reviewed 362 consecutive DMEK cases for failed EK (Descemet stripping endothelial keratoplasty (DSEK) or DMEK), 118 for early EK failure, and 244 for late failure in 333 eyes of 323 patients without penetrating keratoplasty. Rejection and graft survival rates were assessed with Kaplan-Meier analysis.

View Article and Find Full Text PDF

To evaluate the clinical outcomes of cornea transplantation (penetrating keratoplasty, Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, and deep anterior lamellar keratoplasty) using donor corneas stored in Eusol-C hypothermic storage medium compared to corneas stored in organ-culture. : The clinical outcomes of 92 patients who underwent corneal transplantation with human donor corneas stored in Eusol-C medium at 2-8 °C were retrospectively evaluated. The control group consisted of 169 patients who received corneas organ-cultured at 31 °C.

View Article and Find Full Text PDF

The scope of eye banking activities has been expanding with the advances and techniques of keratoplasty. With the popularity of descemet membrane endothelial keratoplasty (DMEK) in the recent decade, there is a need to adopt the preparation of DMEK tissues in the eye banks. This necessitated surgical training of the eye bank technicians, development of infrastructure in the eye bank, innovative methods of graft preparation, and delivery for the surgery at distant surgery centers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!