A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of Proximal Femoral Parameters in Adolescent Idiopathic Scoliosis. | LitMetric

Background: Assessment of the proximal femoral parameters in adolescent idiopathic scoliosis using three-dimensional radiological image reconstructions may allow better characterization than conventional techniques.

Methods: EOS 3D reconstructions of spines and femurs of 320 scoliotic patients (10-18 years old) and 350 control children lacking spinal abnormality were performed and 6 proximal femoral parameters measured.

Results: Individuals with adolescent idiopathic scoliosis showed a small but statistically significant decrease in neck shaft angle (average difference=2.58°) and a higher (0.22°) femoral mechanical axis-femoral shaft angle. When the two sides were compared based on curve direction, greater changes in the neck shaft angle and femoral mechanical axis-femoral shaft angle were found on the side of the convexity.

Conclusions: Patients with adolescent idiopathic scoliosis were found to have a small but significantly lower neck shaft angle and higher femoral mechanical axis-femoral shaft angle, which related to the curve direction. This is postulated to be due to mechanical compensation for altered balance and centre of gravity associated with a scoliosis deformity, although the observed difference likely has negligible clinical effect.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6463608PMC
http://dx.doi.org/10.1155/2019/3948595DOI Listing

Publication Analysis

Top Keywords

shaft angle
24
adolescent idiopathic
16
idiopathic scoliosis
16
proximal femoral
12
femoral parameters
12
neck shaft
12
femoral mechanical
12
mechanical axis-femoral
12
axis-femoral shaft
12
parameters adolescent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!