Background: The goal of this study was to assess patient perspectives and satisfaction with the MiniMed 670G insulin pump. Those participants who used the pump as part of a hybrid closed loop were also asked to provide their views on the automatic feature (auto mode).

Methods: Adults with type 1 diabetes mellitus using the Medtronic™ 670G pump were asked about their experience with the device using a semi-structured survey developed by the research team. Responses were quantified to identify emergent themes.

Results: Seventeen participants used the pump as part of a hybrid closed loop system, while four participants used the pump in combination with a nonintegrated continuous glucose monitoring system. Overall, participants indicated a high level of satisfaction with the pump (14/21) mostly because of improvements in blood glucose (BG) control (15/21). Least liked features were physical design and structure (6/21), frequency of user input (5/21), alert frequency (4/21), and difficulty of use (3/21). Those using the hybrid closed loop were satisfied with the auto mode feature (11/17), mostly because of improvements in BG control (9/17). The least liked features of the auto mode technology were that blood glucose levels remained elevated (5/17) and the frequency of alerts (4/17).

Conclusion: Participants indicated a high level of satisfaction with the pump and its auto mode featured mostly because of improvements in BG control. They also pointed out some key aspects of the device that are of potential clinical or commercial relevance. Additional research is needed to further evaluate users' perspectives on this new device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6835185PMC
http://dx.doi.org/10.1177/1932296819843146DOI Listing

Publication Analysis

Top Keywords

participants pump
12
hybrid closed
12
closed loop
12
auto mode
12
pump
8
insulin pump
8
pump hybrid
8
system participants
8
participants indicated
8
indicated high
8

Similar Publications

Left ventricular (LV) thrombus is a serious complication of myocardial infarction (MI) that can lead to a fetal systemic embolism. Although coronary artery bypass graft surgery (CABG) after MI is widely performed, to our knowledge, there are no reports of LV thrombus in the early postoperative period. Here, we report a rare case of a 70-year-old man who underwent off-pump coronary artery bypass grafting (OPCAB) for unstable angina pectoris with reduced left ventricular ejection fraction (LVEF).

View Article and Find Full Text PDF

The Black Esophagus: A Rare Case Presentation.

Cureus

December 2024

Gastroenterology and Hepatology, Saint Peter's University Hospital, New Brunswick, USA.

Acute esophageal necrosis (AEN), also known as black esophagus or Gurvits syndrome, is an uncommon endoscopic finding characterized by diffuse, circumferential, black discoloration of the esophagus that terminates at the gastroesophageal junction. The incidence of AEN has been reported to be 0-0.2% in autopsy series and up to 0.

View Article and Find Full Text PDF

Introduction: Pembrolizumab stands as a first-line option for patients with advanced non-small cell lung cancer (NSCLC) and high programmed death-ligand 1 (PD-L1) expression (PD-L1 ≥50%). Several factors such as antibiotic exposure, low body mass index (BMI), certain metastatic location or poor performance status may influence outcomes.

Methods: We conducted a multicenter retrospective analysis in a cohort of patients with advanced high PD-L1 expression NSCLC treated with first-line pembrolizumab in clinical practice.

View Article and Find Full Text PDF

Background & objectives The COVID-19 pandemic underscores the significance of vaccination in mitigating disease spread, with Covishield and Covaxin serving as pivotal vaccines in India. Breast milk, rich in vital antibodies like IgA and IgG, plays a crucial role in enhancing the immune defence of breastfeeding infants. However, limited research exists on the antibody responses in breast milk among individuals receiving single versus double doses of the COVID-19 vaccine.

View Article and Find Full Text PDF

Fear of hypoglycemia and sleep in children with type 1 diabetes and their parents.

Front Endocrinol (Lausanne)

December 2024

Department of Pediatric Diabetes and Endocrinology, Clinique Pédiatrique, Centre Hospitalier, Luxembourg, Luxembourg.

Aims: To compare impact of pump treatment and continuous glucose monitoring (CGM) with predictive low glucose suspend (SmartGuard) or user initiated CGM (iscCGM) on sleep and hypoglycemia fear in children with type 1 Diabetes and parents.

Methods: Secondary analysis of data from 5 weeks pump treatment with iscCGM (A) or SmartGuard (B) open label, single center, randomized cross-over study was performed. At baseline and end of treatment arms, sleep and fear of hypoglycemia were evaluated using ActiGraph and questionnaires.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!