An intelligent optical performance monitor using multi-task learning based artificial neural network (MTL-ANN) is designed for simultaneous OSNR monitoring and modulation format identification (MFI). Signals' amplitude histograms (AHs) after constant module algorithm are selected as the input features for MTL-ANN. The results obtained from simulation and experiment of NRZ-OOK, PAM4 and PAM8 signals demonstrate that MTL-ANN could achieve OSNR monitoring and MFI simultaneously with higher accuracy and stability compared with single-task learning based ANNs (STL-ANNs). The results show an MFI accuracy of 100% for the three modulation formats under consideration. Furthermore, OSNR monitoring with mean-square error (MSE) of 0.12 dB and accuracy of 100% is achieved while regarding it as regression problem and classification problem, respectively. In this intelligent optical performance monitor, only a single MTL-ANN is deployed, which enables reduced-complexity optical performance monitor (OPM) devices for multi-parameters estimation in future heterogeneous optical network.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.011281DOI Listing

Publication Analysis

Top Keywords

optical performance
16
performance monitor
16
intelligent optical
12
learning based
12
osnr monitoring
12
monitor multi-task
8
multi-task learning
8
based artificial
8
artificial neural
8
neural network
8

Similar Publications

Proposing an effective modification strategy to optimize catalyst reaction potentials is crucial for enhancing catalytic performance. In this study, we employed a combined approach by adjusting nitrogen dopants in the first- and second-shell environments to tailor the OER/ORR reaction potentials of FeN, CoN, and NiN active centers. Using density functional theory simulations, we systematically compared the effects of first- and second-shell nitrogen dopants on the local atomic/electronic structures and catalytic activities.

View Article and Find Full Text PDF

Hydrogenated isoprenoids are found in a range of biologically important natural products, such as isoprenoid quinones, chlorophyll, vitamin E, and dolichol. In this study, a new method was developed for determining the chirality of the tetrahydrogenated isoprenoid (THI) structures of two natural products, namely heptaprenylcycli-14,18-diene and (22,5,9,13,17)-6,10,14,18,22,26-hexamethylheptacosa-5,9,13,17-tetraen-2-one, for which the chiral carbon centres have never been elucidated. Our research group previously isolated the former sesquarterpene from , while the latter was isolated as a new polyprenyl acetone from in the current study.

View Article and Find Full Text PDF

In endemic regions, intra-orbital hydatid cysts are a rare manifestation of Echinococcus granulosus infection, classically disturbing the liver and lungs. This report details a patient's case with an intra-orbital cyst presenting. Diagnostic imaging revealed a cystic lesion causing optic nerve displacement.

View Article and Find Full Text PDF

Introduction: The molecular pathogenesis of ocular adnexal mucosa-associated lymphoid tissue (MALT) lymphoma and IgG4-related ophthalmic disease (IgG4-ROD) remains incompletely understood. Differentiating between the two diseases is vital given that the diagnostic evaluation and treatment approaches can vary significantly; this difficulty in distinction is exacerbated by the absence of specific biomarkers. This study aimed to investigate the differences between these two diseases based on their cellular composition, transcriptional heterogeneity, and the immune microenvironment using single-cell RNA transcriptional sequencing (scRNA-seq) technology.

View Article and Find Full Text PDF

Introduction: Laser refractive surgeries are a safe option for low-to-moderate refractive corrections, providing excellent visual outcomes. Over the years, various procedures have been introduced into clinical practice, but the most performed today remain Photorefractive Keratectomy (PRK), Laser Keratomileusis (LASIK), and Small Incision Lenticule Extraction (SMILE). Although laser refractive treatments are considered safe, clinicians have focused on the risk of post-surgical ectasia, a rare but serious complication.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!