Background/aim: There is continuing interest in engineering esthetic labial archwires. The aim of this study was to coat nickel-titanium (NiTi) and beta-titanium (β-Ti), also known as titanium molybdenum (TMA), archwires by plasma electrolytic oxidation (PEO) and to analyze the characteristics of the PEO-surfaces.

Materials And Methods: PEO-coatings were generated on 0.014-inch NiTi and 0.19 × 0.25-inch β-Ti archwires. The surfaces were analyzed by scanning electron microscopy and stereomicroscopy. Cytocompatibility testing was performed with ceramized and untreated samples according to EN ISO 10993-5 in XTT-, BrdU- and LDH-assays. The direct cell impact was analyzed using LIVE-/DEAD-staining. In addition, the archwires were inserted in an orthodontic model and photographs were taken before and after insertion.

Results: The PEO coatings were 15 to 20 µm thick with a whitish appearance. The cytocompatibility analysis revealed good cytocompatibility results for both ceramized NiTi and β-Ti archwires. In the direct cell tests, the ceramized samples showed improved compatibility as compared to those of uncoated samples. However, bending of the archwires resulted in loss of the PEO-surfaces. Nevertheless, it was possible to insert the β-Ti PEO-coated archwire in an orthodontic model without loss of the PEO-ceramic.

Conclusion: PEO is a promising technique for the generation of esthetic orthodontic archwires. Since the PEO-coating does not resist bending, its clinical use seems to be limited so far to orthodontic techniques using straight or pre-bent archwires.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539843PMC
http://dx.doi.org/10.3390/ma12091403DOI Listing

Publication Analysis

Top Keywords

archwires
9
orthodontic archwires
8
plasma electrolytic
8
electrolytic oxidation
8
β-ti archwires
8
direct cell
8
orthodontic model
8
orthodontic
5
surface characteristics
4
characteristics esthetic
4

Similar Publications

Impact of chlorine dioxide and chlorhexidine mouthwashes on friction and surface roughness of orthodontic stainless steel wires: an in-vitro comparative study.

F1000Res

January 2025

Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences, Manipal Academy of Higher Education, Manipal, Karanataka, 576104, India.

Objectives: Good oral hygiene measures are important for successful orthodontic treatment. They involve various types of mouthwashes which have been reported to cause alteration of mechanical properties of archwires. This study aimed to evaluate the effects of a new kind of chlorine-dioxide-containing mouthwash on the mechanical properties and surface morphology of stainless steel orthodontic archwires against the already prevalent chlorhexidine mouthwash in the market.

View Article and Find Full Text PDF

Objectives: Apical root resorption and alveolar bone loss are potential complications associated with orthodontic treatment. This study aimed to assess apical root resorption and alveolar bone height following orthodontic treatment of moderate crowding with labial vs. lingual fixed appliances using CBCT imaging.

View Article and Find Full Text PDF

Effectiveness of Transcutaneous Electric Nerve Stimulation for Controlling Pain after the Archwire Placement.

Natl J Maxillofac Surg

November 2024

Department of Orthodontics and Dentofacial Orthopaedics, Saraswati Dental College, Lucknow, Uttar Pradesh, India.

Introduction: The aim of the study was to evaluate the effectiveness of transcutaneous electric nerve stimulation (TENS) for controlling pain after the archwire placement and then comparison between the placebo, extra-oral, and intra-oral group depending upon the electrode placement.

Materials And Methods: The study consists of a sample size of 90 patients who were further divided into three groups. Each group had 30 samples each, and the groups were divided into placebo group, extra-oral TENS group, and intra-oral TENS group.

View Article and Find Full Text PDF

Background And Objective: According to microbiological investigations, microorganisms, especially Lactobacillus strains, considerably increase after using fixed orthodontic appliances. One of the Lactobacilli bacteria found in the oral cavity is . The purpose of this study was to compare the adhesion of to metal and ceramic brackets with coated and uncoated nickel titanium (NiTi) orthodontic archwires.

View Article and Find Full Text PDF

A novel appliance for Class II dentoalveolar correction.

J Orthod

January 2025

Private Practice, Jerusalem, Israel.

In recent years, a segmental approach to Class II correction has gained popularity among orthodontists. This concept is best represented by the Carrière Motion 3D™ Class II Appliance (CMA), which is an efficient and effective appliance for the treatment of Class II malocclusions. Although it is original and innovative, it also has some inherent flaws that can potentially interfere with its daily use.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!