Cascaded Raman fiber lasers based on random distributed feedback (RDFB) are proven to be wavelength agile, enabling high powers outside rare-earth doped emission windows. In these systems, by simply adjusting the input pump power and wavelength, high-power lasers can be achieved at any wavelength within the transmission window of optical fibers. However, there are two primary limitations associated with these systems, which in turn limits further power scaling and applicability. Firstly, the degree of wavelength conversion or spectral purity (percentage of output power in the desired wavelength band) that can be achieved is limited. This is attributed to intensity noise transfer of input pump source to Raman Stokes orders, which causes incomplete power transfer reducing the spectral purity. Secondly, the output power range over which the high degree of wavelength conversion is maintained is limited. This is due to unwanted Raman conversion to the next Stokes order with increasing power. Here, we demonstrate a high-power, cascaded Raman fiber laser with near complete wavelength conversion over a wide wavelength and power range. We achieve this by culmination of two recent developments in this field. We utilize our recently proposed filtered feedback mechanism to terminate Raman conversion at arbitrary wavelengths, and we use the recently demonstrated technique (by J Dong and associates) of low-intensity noise pump sources (Fiber ASE sources) to achieve high-purity Raman conversion. Pump-limited output powers >34W and wavelength conversions >97% (highest till date) were achieved over a broad - 1.1μm to 1.5μm tuning range. In addition, high spectral purity (>90%) was maintained over a broad output power range (>15%), indicating the robustness of this laser against input power variations.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.27.009725DOI Listing

Publication Analysis

Top Keywords

raman fiber
12
wavelength conversion
12
spectral purity
12
output power
12
power range
12
raman conversion
12
wavelength
10
power
10
high-power cascaded
8
fiber laser
8

Similar Publications

This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging.

View Article and Find Full Text PDF

Plastic pollution, particularly from microplastics (MPs) and nanoplastics (NPs), has become a critical environmental and health concern due to their widespread distribution, persistence, and potential toxicity. MPs and NPs originate from primary sources, such as cosmetic microspheres or synthetic fibers, and secondary fragmentation of larger plastics through environmental degradation. These particles, typically less than 5 mm, are found globally, from deep seabeds to human tissues, and are known to adsorb and release harmful pollutants, exacerbating ecological and health risks.

View Article and Find Full Text PDF

Coexistence Demonstration and Wavelength Dependency Analysis of S-Band CV-QKD Signal with Fully Loaded C+L-Band DWDM Signals.

Entropy (Basel)

January 2025

Advanced Network Research Laboratories, NEC Corporation, Kawasaki 211-8666, Kanagawa, Japan.

We demonstrated the coexistence of an S-band CV-QKD signal with fully loaded C+L-band classical signals for the first time. The secret key rate of the S-band QKD system was 986 kbps with the C+L-band WDM signals transmitted through a 20 km G.654.

View Article and Find Full Text PDF

Five commercially available cut-resistant gloves were sourced from four different worldwide manufacturers which were advertised to contain graphene. A method was developed to assess the fibers composing each glove, including dissolution of the constituent fibers using sulfuric acid or liquid paraffin at elevated temperature, to extract and analyze particle additives. Scanning electron microscopy with energy-dispersive X-ray spectroscopy was applied to fibers and extracted particles for morphological and elemental analysis; Raman spectroscopy was applied to discern the composition of carbonaceous materials for the ultimate purpose of identifying any graphenic additives.

View Article and Find Full Text PDF

Availability of a suitable tool for carrying out non-invasive measurement of Raman signatures in situ, from biological tissues having low Raman cross section is a clinically unmet need faced with manifold challenges. A Raman probe can prove to be an invaluable component of clinical Raman diagnostic systems. We present development of a Raman probe capable of measuring artefact free Raman spectra of biological tissues in situ.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!