Pediatric cone beam CT on Varian Halcyon and TrueBeam radiotherapy systems: radiation dose and positioning accuracy evaluations.

J Radiol Prot

Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142 People's Republic of China.

Published: September 2019

Medical exposure to ionizing irradiation has become a recognised carcinogenic risk. Balancing the concomitant imaging dose and positioning accuracy is critical in image-guided-radiotherapy (IGRT) especially for children, whose higher biological susceptibility and longer expected life make them more vulnerable to develop secondary cancer. This work aims to evaluate and benchmark the imaging dose and positioning accuracy of a new MV cone-beam-CT (CBCT)-guided IGRT system, Varian Halcyon, against conventional kV CBCT. Weighted-CT-dose-index (CTDI) were measured for Varian TrueBeam kV CBCT, and computed for Halcyon MV CBCT using Eclipse system as validated before. Simulating the IGRT workflow, the positioning accuracy of correcting a known shift was tested on various regions of 1-year, 5-year and adult anthropomorphic phantoms, respectively. Inter-scanner and inter-protocol comparisons of dose and accuracy were performed. kV CTDI for 'Head', 'Thorax', 'Pelvis' and 'Image Gently' (in CTDI/CTDI phantoms, respectively) protocols were measured as 4.5 mGy, 5.4 mGy, 19.3 mGy, and 1.1 mGy/0.5 mGy, respectively. Using 'High Quality' mode, MV CTDI in the CTDI and CTDI phantoms were computed as 84.5 mGy and 63.8 mGy (imaging length = 28 cm), 68.8 mGy and 55.5 mGy (imaging length = 16 cm), respectively, which were about twice of 'Low Dose' mode. The maximum positioning deviation observed on Halcyon was 0.51 mm ('Low Dose' adult thorax), which was lower than that of standard (0.58 mm, 'Pelvis' adult pelvis) and 'Image Gently' kV CBCT (1.57 mm, adult pelvis). Accuracy of 'Image Gently' kV CBCT head & neck and thoracic imaging were clinically acceptable for adults (maximum deviation = 0.54 mm, adult thorax). Complying with Image Gently campaign, dose-efficient protocols should be used for pediatric IGRT, achieving comparable positioning accuracy on the new Halcyon MV CBCT system relative to the conventional kV CBCT.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/ab1e74DOI Listing

Publication Analysis

Top Keywords

positioning accuracy
20
dose positioning
12
'image gently'
12
varian halcyon
8
imaging dose
8
conventional cbct
8
halcyon cbct
8
mgy
8
ctdi ctdi
8
mgy imaging
8

Similar Publications

Aim: Successful deep brain stimulation (DBS) requires precise electrode placement. However, brain shift from loss of cerebrospinal fluid or pneumocephalus still affects aim accuracy. Multidetector computed tomography (MDCT) provides absolute spatial sensitivity, and intraoperative cone-beam computed tomography (iCBCT) has become increasingly used in DBS procedures.

View Article and Find Full Text PDF

Significant strides have been made in emotion recognition from Electroencephalography (EEG) signals. However, effectively modeling the diverse spatial, spectral, and temporal features of multi-channel brain signals remains a challenge. This paper proposes a novel framework, the Directional Spatial and Spectral Attention Network (DSSA Net), which enhances emotion recognition accuracy by capturing critical spatial-spectral-temporal features from EEG signals.

View Article and Find Full Text PDF

Background: Accurate segmentation of rib fractures represents a pivotal procedure within surgical interventions. This meticulous process not only mitigates the likelihood of postoperative complications but also facilitates expedited patient recuperation. However, rib fractures in computed tomography (CT) images exhibit an uneven morphology and are not fixed in position, posing difficulties in segmenting fractures.

View Article and Find Full Text PDF

Phosphorothioate (PS) modifications in single-guided RNA (sgRNA) are crucial for genome editing applications using the CRISPR/Cas9 system. These modifications may enhance sgRNA stability, pharmacokinetics, and binding to targets, thereby facilitating the desired genetic alterations. Incorporating multiple PS groups at varying positions may introduce chiral centers into the sgRNA backbone, resulting in a complex mixture of constitutional- and stereoisomers that challenges current analytical capabilities for reliable identification and quantification.

View Article and Find Full Text PDF

Accurately predicting satellite clock deviation is crucial for improving real-time location accuracy in a GPS navigation system. Therefore, to ensure high levels of real-time positioning accuracy, it is essential to address the challenge of enhancing satellite clock deviation prediction when high-precision clock data is unavailable. Given the high frequency, sensitivity, and variability of space-borne GPS satellite atomic clocks, it is important to consider the periodic variations of satellite clock bias (SCB) in addition to the inherent properties of GPS satellite clocks such as frequency deviation, frequency drift, and frequency drift rate to improve SCB prediction accuracy and gain a better understanding of its characteristics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!