A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A highly sensitive and low-background fluorescence assay for pesticides residues based on hybridization chain reaction amplification assisted by magnetic separation. | LitMetric

Due to the concern over food safety, it is important to detect the pesticides residues in agricultural products. Here, a highly sensitive and low background fluorescent strategy for the detection of pesticides residues has been developed. The fluorescence intensity of N-methyl mesoporphyrin IX (NMM) binding G-quadruplex could be turn off because of inhibiting effect of the pesticides on the acetylcholinesterase (AChE) activity. For that, four single-stranded DNAs (named linker, trigger, H1 and H2, respectively) are rational designed and T-Hg-T mismatches duplex DNAs as a recognizer combined with the separation of magnetic beads. The design of hybridization chain reaction (HCR) amplification strategy assisted by magnetic separation has been adopted to improve the detection sensitivity. In the presence of pesticides, the amount of the thiol group generated by hydrolysis reaction of acetylcholine (ACh) is reduced, lead to release of less trigger DNA. Therefor subsequent HCR process is retarded with decreased fluorescence intensity. The reduced fluorescence intensity has a quantitative relationship with the pesticide concentration. The limit of detection of chlorpyrifos was estimated to be 2.0 ng ml. It has been applied to detect the pesticides residues in real samples.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2050-6120/ab1e7aDOI Listing

Publication Analysis

Top Keywords

pesticides residues
16
fluorescence intensity
12
highly sensitive
8
hybridization chain
8
chain reaction
8
assisted magnetic
8
magnetic separation
8
detect pesticides
8
pesticides
6
sensitive low-background
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!