Background: Influenza is a major cause of morbidity and mortality in patients diagnosed with heart failure. The aim of this study was to evaluate the effectiveness of influenza vaccination in this population in terms of reduction in all-cause mortality and rate of hospitalization.

Methods: We conducted a systematic review and meta-analysis using PubMed and EMBASE entries from January of 2000 through April 2018. Publication bias was examined using the Egger's regression test. Statistical heterogeneity was examined using the Higgins statistic. Subgroup analyses were performed to examine the effect of vaccination during the influenza and noninfluenza seasons.

Results: We identified 8 studies that included a total of 82 354 patients with heart failure. In patients with heart failure who were vaccinated against influenza, we found a reduced risk of all-cause mortality (hazard ratio [HR], 0.69; 95% confidence interval [CI], 0.51-0.87). No evidence of publication bias was found, and the effect was more pronounced during influenza season (HR, 0.49; 95% CI, 0.30-0.69), compared with noninfluenza season (HR, 0.79; 95% CI, 0.68-0.89). In terms of heart failure hospitalizations, we did not identify a statistically significant difference between the cohorts (HR, 0.62; 95% CI, 0.00-1.23).

Conclusions: Influenza vaccination was associated with a decreased risk of all-cause mortality in patients with heart failure, and this effect was more prominent during the influenza season.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6483130PMC
http://dx.doi.org/10.1093/ofid/ofz159DOI Listing

Publication Analysis

Top Keywords

heart failure
24
patients heart
16
influenza vaccination
12
all-cause mortality
12
influenza
8
systematic review
8
review meta-analysis
8
mortality patients
8
publication bias
8
risk all-cause
8

Similar Publications

Type 2 diabetes (T2D) frequently coexists with cardiorenal complications. Therefore, a holistic approach to patient management is required, with specialists such as primary care physicians, cardiologists, endocrinologists, and nephrologists working together to provide patient care. Although glycemic control is important in the management of T2D, patients with T2D and acceptable glycemic control are still at risk from cardiovascular (CV) events such as stroke, heart attack, and heart failure (HF).

View Article and Find Full Text PDF

Background: Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys).

Methods: This was a prospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP).

View Article and Find Full Text PDF

Left atrial strain (LAS) was recently introduced as a parameter that reflects on left atrial function. Consequently, changes in LAS can inform the development of cardiovascular diseases, hence providing a window for non-invasive and cost-effective testing of these diseases and their complications at early stages of development, potentially offering a segway towards preventive interventions. LAS has yet to be implemented into standard practice.

View Article and Find Full Text PDF

Background: Little is known about how younger and older hospitalized patients differ with respect to reasons for admission, comorbidities, diagnostics, treatment and intercurrent problems.

Objective: The aim of the study was to compare the previously named characteristics in the clinical profile of patients > 90 years old (nonagenarians) with a control group of patients 70-75 years old admitted to an emergency hospital department for internal medicine and cardiology.

Material And Method: The study included all consecutive nonagenarians and gender-matched control patients who were admitted during 2011.

View Article and Find Full Text PDF

Background: Noninferiority of omitting intraoperative defibrillation threshold (DFT) testing has been documented for transvenous implantable cardioverter defibrillators (ICD) whereas data for the subcutaneous-ICD (S-ICD) regarding the need for DFT testing, especially during S-ICD generator replacement, is not available.

Methods: A total of 112 consecutive patients who underwent S-ICD generator replacement and routine testing were included in this retrospective single-center study and analyzed regarding the outcome of intraoperative DFT.

Results: The majority of patients (87.