This paper aims to present a novel full-eye biomechanical material model that incorporates the characteristics of ocular tissues at microstructural level, and use the model to analyse the age-related stiffening in tissue behaviour. The collagen content in ocular tissues, as obtained using X-ray scattering measurements, was represented by sets of Zernike polynomials that covered both the cornea and sclera, then used to reconstruct maps of collagen fibril magnitude and orientation on the three-dimensional geometry of the eye globe. Fine-mesh finite-element (FE) models with eye-specific geometry were built and supported by a user-defined material model (UMAT), which considered the regional variation of fibril density and orientation. The models were then used in an iterative inverse modelling study to derive the material parameters that represent the experimental behaviour of ocular tissues from donors aged between 50 and 90 years obtained in earlier ex vivo studies. Sensitivity analysis showed that reducing the number of directions that represented the anisotropy of collagen fibril orientation at each X-ray scattering measurement point from 180 to 16 would have limited and insignificant effect on the FE solution (0.08%). Inverse analysis resulted in material parameters that provided a close match with experimental intraocular pressure-deformation behaviour with a root mean square of error between 3.6% and 4.3%. The results also demonstrated a steady increase in mechanical stiffness in all ocular regions with age. A constitutive material model based on distributions of collagen fibril density and orientation has been developed to enable the accurate representation of the biomechanical behaviour of ocular tissues. The model offers a high level of control of stiffness and anisotropy across ocular globe, and therefore has the potential for use in planning surgical and medical procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6544887PMC
http://dx.doi.org/10.1098/rsif.2018.0685DOI Listing

Publication Analysis

Top Keywords

ocular tissues
16
behaviour ocular
12
material model
12
collagen fibril
12
x-ray scattering
8
fibril density
8
density orientation
8
material parameters
8
ocular
7
behaviour
5

Similar Publications

osteomyelitis in a dog.

Can Vet J

January 2025

Department of Comparative, Diagnostic, and Population Medicine, College of Veterinary Medicine, University of Florida, 2015 SW 16th Avenue, Gainesville, Florida 32608, USA (Whitman); Gulf Coast Veterinary Specialists, 8042 Katy Freeway, Houston, Texas 77024, USA (Wilson); Department of Small Animal Clinical Sciences, Texas A&M School of Veterinary Medicine and Biomedical Sciences, 4474 TAMU, College Station, Texas 77843, USA (Heseltine).

Canine systemic protothecosis is an uncommon disease caused by spp., which are saprophytic algae occurring ubiquitously in nature. Infection occurs most commonly in immunocompromised animals.

View Article and Find Full Text PDF

Stargardt disease is a currently untreatable, inherited neurodegenerative disease that leads to macular degeneration and blindness due to loss-of-function mutations in the ABCA4 gene. We have designed a dual adeno-associated viral vector encoding a split-intein adenine base editor to correct the most common mutation in ABCA4 (c.5882G>A, p.

View Article and Find Full Text PDF

Purpose: Mechanical stress on the ocular surface, such as from eye-rubbing, has been reported to lead to inflammation and various ocular conditions. We hypothesized that the mechanosensitive Piezo1 channel in the conjunctival epithelium contributes to the inflammatory response at the ocular surface after receiving mechanical stimuli.

Methods: Human conjunctival epithelial cells (HConjECs) were treated with Yoda1, a Piezo1-specific agonist, and various allergens to measure cytokine expression levels using qRT-PCR.

View Article and Find Full Text PDF

Radiotherapy is one of the conventional treatments for head and neck malignancies. Despite the implementation of protective measures to minimize the detrimental impact on healthy tissues surrounding the radiation site, radiation keratopathy remains a prevalent complication. We aimed to establish a mouse model of radiation keratopathy to characterize the pathophysiology of the disease and enable future identification of potential treatments.

View Article and Find Full Text PDF

Purpose: To evaluate an alternative surgical approach for Port Delivery System with ranibizumab (PDS) implant and a novel application of Iridex laser system in Gottingen minipig model.

Methods: A total of seventeen male minipigs (Part 1: 9 animals in non-recovery and Part 2: 8 animals observed for 8-days post-surgery Part 2) received PDS implant insertion into each eye. The effect of Iridex 810 nm infrared diode laser with varying energy (power or duration) on transscleral pars plana ablation, surrounding ocular tissue and postsurgical vitreous hemorrhage (VH) was investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!