Utility of Magnetic Resonance Imaging in Differentiating Cerebrospinal Fluid Leak from Middle Ear Effusion.

Otolaryngol Head Neck Surg

1 Department of Otolaryngology-Head and Neck Surgery, College of Medicine, University of Cincinnati, Cincinnati, Ohio, USA.

Published: September 2019

Objective: To demonstrate the clinical utility, sensitivity, and specificity of standard magnetic resonance imaging (MRI) sequences in differentiating temporal bone cerebrospinal fluid leaks from all other middle ear effusions.

Study Design: Retrospective imaging review.

Setting: Academic medical center.

Subjects: Patients with cerebrospinal fluid leaks or other middle ear effusions who also underwent MRI.

Methods: Patients were assigned to cerebrospinal fluid leak and other effusion cohorts based on clinical course, findings at surgery/myringotomy, and beta-2 transferrin fluid analysis. Reviewers blinded to the clinical outcome examined T1-weighted, T2-weighted, diffusion-weighted, fluid-attenuated inversion recovery (FLAIR), and 3-dimensional (3D) acquired T2-weighted MRI sequences. For each sequence, fluid imaged in the temporal bone was graded as either similar or dissimilar in signal intensity to cerebrospinal fluid in the adjacent subarachnoid space. Signal similarity was interpreted as being diagnostic of a leak. Test characteristics in predicting the presence of a leak were calculated for each series.

Results: Eighty patients met criteria (41 leaks, 39 other effusions). The 3D T2 series was 76% sensitive and 100% specific in diagnosing a leak, and FLAIR was 44% sensitive and 100% specific. The T1-weighted (73% sensitive, 69% specific), T2-weighted (98% sensitive, 5.1% specific), and diffusion-weighted (63% sensitive, 66% specific) series were less useful.

Conclusions: MRI, with attention to 3D T2 and FLAIR series, is a noninvasive and highly specific test for diagnosing cerebrospinal fluid leak in the setting of an indeterminate middle ear effusion.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0194599819847153DOI Listing

Publication Analysis

Top Keywords

cerebrospinal fluid
24
middle ear
16
fluid leak
12
magnetic resonance
8
resonance imaging
8
fluid
8
ear effusion
8
mri sequences
8
temporal bone
8
fluid leaks
8

Similar Publications

Antithrombin III deficiency and idiopathic intracranial hypertension: a case report.

J Med Case Rep

January 2025

Headache Department, Iranian Center of Neurological Research, Neuroscience Institute, Tehran University of Medical Sciences, Tehran, Iran.

Background: Idiopathic intracranial hypertension (IIH) is a condition where the pressure of the cerebrospinal fluid in the brain increases without a known cause. It typically affects adults but can also occur in adolescents and children, although it is less common. Numerous elements, including coagulopathy, have been documented in previous cases as potential etiological factors of IIH.

View Article and Find Full Text PDF

Background: Vanishing white matter disease (VWMD) is a rare autosomal recessive leukoencephalopathy. It is typified by a gradual loss of white matter in the brain and spinal cord, which results in impairments in vision and hearing, cerebellar ataxia, muscular weakness, stiffness, seizures, and dysarthria cogitative decline. Many reports involve minors.

View Article and Find Full Text PDF

Background: Diagnostics for neurodegenerative diseases lack non-invasive approaches suitable for early-stage biochemical screening and routine examination of neuropathology. Biomarkers of neurodegenerative diseases pass through the brain-nose interface (BNI) and accumulate in nasal secretion. Sample collection from the brain-nose interface presents a compelling prospect as basis for a non-invasive molecular diagnosis of neuropathologies.

View Article and Find Full Text PDF

Background: Certain peripheral proteins are believed to be involved in the development of Alzheimer's disease (AD), but the roles of other new protein biomarkers are still unclear. Current treatments aim to manage symptoms, but they are not effective in stopping the progression of the disease. New drug targets are needed to prevent Alzheimer's disease.

View Article and Find Full Text PDF

Identifying the appropriate measurement environment for laser speckle flowmetry of cerebral blood flow in rats.

Brain Res

January 2025

Department of Neurosurgery, Division of Functional and Integrative Medicine, Department of Neurosurgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan.

Laser speckle flowmetry (LSF) is a noninvasive tool for cerebral blood flow (CBF) measurement via a cranial bone window. LSF is influenced by various factors including the extent of removal of bone and dura mater and tissue wetness in the bone window. In this study, we aimed to characterize the effect of these conditions on LSF signals and identify optimal measurement conditions for CBF LSF measurements in rats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!