The assessment of aortic root dimensions is important in cardiac pre-participation screening. Scaling of cardiac dimensions removes the impact of body size allowing meaningful inter/intra group comparisons. Developing appropriate scaling approaches, scaling variables and extending the application to major vessels is warranted so underlying pathology can be detected and managed appropriately. The study aims to define relationships between aortic root dimensions and body surface area/height. Two hundred and twenty elite Rugby Football League athletes were recruited. All participants completed anthropometric assessments, a 12-lead ECG and echocardiogram. Aortic root was measured at the aortic annulus, sinus of valsalva, sinotubular junction and the proximal ascending aorta. Linear and allometric scaling were performed on the relationship between aortic measurements and body surface area/height. Absolute aortic root measurements fell within normal population data (mean ± standard deviation (range): aortic annulus: 22 ± 2 (17-28) mm, sinus of valsalva: 28 ± 3 (20-38) mm, sinotubular junction: 22 ± 3 (14-33) mm, proximal ascending aorta: 22 ± 3 (15-31) mm). Linear scaling to height produced size-independent indices at all aortic measurement sites (P < 0.05). Conversely, linear scaling using body surface area did not produce size-independent indices at any site (P > 0.05). Allometric scaling, using both body surface area and height, produced size-independent indices at all sites (P < 0.05). We recommend linearly scaling aortic root dimensions to height in elite Rugby Football League athletes and discourage the use of body surface area as a linear scaling quantity. Allometric scaling is also effective when using both body surface area and height.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6475976 | PMC |
http://dx.doi.org/10.1177/1742271X18818607 | DOI Listing |
Acad Radiol
January 2025
Medical Image Processing Group, 602 Goddard building, 3710 Hamilton Walk, Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 (M.L., M.A., J.K.U., Y.T., C.W., N.P., S.M., D.A.T.). Electronic address:
Rationale And Objectives: Cardiovascular toxicity is a well-known complication of thoracic radiation therapy (RT), leading to increased morbidity and mortality, but existing techniques to predict cardiovascular toxicity have limitations. Predictive biomarkers of cardiovascular toxicity may help to maximize patient outcomes.
Methods: The machine learning optimal biomarker (OBM) method was employed to predict development of cardiotoxicity (based on serial echocardiographic measurements of left ventricular ejection fraction and longitudinal strain) from computed tomography (CT) images in patients with thoracic malignancy undergoing RT.
Int J Cardiol
January 2025
Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus MC, Rotterdam, the Netherlands; European Reference Network for Rare, Low Prevalence and Complex Diseases of the Heart (ERN GUARD-Heart), Amsterdam, the Netherlands.
Background: Little is known about the very long-term outcome in Tetralogy of Fallot (ToF) patients.
Objectives: To prospectively evaluate clinical outcome and quality-of-life after surgical repair of ToF.
Methods: Single-centre, longitudinal cohort-study evaluating every decade 144 ToF patients who underwent surgical repair <15 years of age between 1968 and 1980.
Radiol Case Rep
March 2025
Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, State University of New York (SUNY), Downstate Health Sciences University, Brooklyn, NY, USA.
Extensive congenital pulmonary airway malformation (CPAM) of the left fetal lung and associated marked dextroposition of the fetal heart were noted at 21 weeks' gestation. The right fetal lung appeared compressed with the cardiomediastinal shift angle measuring approximately 20 degrees. Potential subsequent right pulmonary hypoplasia was considered.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
Cardiology Department, Hospital Universitario Quirónsalud Madrid, Calle Diego de Velázquez, 1, Madrid 28223, Spain.
Aims: To assess the reproducibility of 4D-Flow cardiac magnetic resonance (CMR) parameters in the descending thoracic aorta-DTAo-(regurgitant fraction [RF], end-diastolic reverse flow [EDRF], and holodiastolic flow reversal [HDR]), and the relationship with RF in the sinotubular junction (STJ), and the left ventricular end-diastolic volume index (LVEDVI) in patients with chronic aortic regurgitation (AR).
Methods And Results: A descriptive study of these variables was conducted. A receiver operating characteristic curve was used to determine the optimal cut-off point.
Catheter Cardiovasc Interv
January 2025
Department of Cardiac Anesthesia, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Acute coronary occlusion during transcatheter aortic valve implantation (TAVI) is an unwarranted complication associated with high mortality. The current TAVI practices recommend a multidetector computed tomography (MDCT) evaluation of the aortic valve, the left ventricular outflow tract, and the aortic root to determine the conventional risk factors for coronary obstruction like low-lying coronary ostia and narrow sinuses of Valsalva, mandating prophylactic coronary protection or native valve leaflet modification in high-risk patients. Despite optimal anatomy, acute coronary occlusion can still occur due to multiple mechanisms, one of which is coronary embolism due to thrombus, calcium, or native aortic valve fragments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!