A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of long-term clinical outcomes in multivessel coronary artery disease patients treated either with bioresoarbable polymer sirolimus-eluting stent or permanent polymer everolimus-eluting stent: 5-year results of the CENTURY II randomized clinical trial. | LitMetric

Objectives: To assess the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster), in comparison to a benchmark everolimus-eluting, permanent polymer stent (PP-EES; Xience), in a prespecified subgroup of patients with multivessel coronary artery disease (MVD) enrolled in the CENTURY II trial.

Background: The use of coronary stenting in high-risk subgroups, like MVD patients, is rising. The clinical evidence, including long-term comparative analysis of the efficacy and safety benefits of different new-generation drug eluting stents, however, remains insufficient.

Methods: Among 1,119 patients (intention-to-treat) enrolled in the CENTURY II prospective, randomized, single-blind, multicenter trial, a prespecified subgroup of 456 MVD patients were allocated by stratified randomization to treatment with BP-SES (n = 225) or PP-EES (n = 231). The previously reported primary endpoint of this study was freedom from target lesion failure (TLF: a composite of cardiac death, target vessel-related myocardial infarction [MI] and clinically-indicated target lesion revascularization) at 9 months.

Results: In this MVD substudy, baseline patient, lesion and procedure characteristics were similar between the treatment arms. At 1 and 5 years, both BP-SES and PP-EES displayed low and comparable rates of TLF (5.3 vs. 7.8%; p = .29 and 10.2 vs. 13.4%; p = .29), and definite or probable stent thrombosis (0.4 vs. 1.3%; p = .33 and 0.9 vs. 1.7%; p = .43), respectively. Composite endpoint of cardiac death and MI, and patient-oriented composite endpoint of any death, MI, and coronary revascularizations were also similar.

Conclusions: These results confirm good long-term safety and efficacy of the studied bioresorbable polymer stent in this high-risk patient population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7064960PMC
http://dx.doi.org/10.1002/ccd.28224DOI Listing

Publication Analysis

Top Keywords

multivessel coronary
8
coronary artery
8
artery disease
8
sirolimus-eluting stent
8
permanent polymer
8
long-term safety
8
safety efficacy
8
bioresorbable polymer
8
polymer stent
8
prespecified subgroup
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!