A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preventing Harm From Fluoroscopically Guided Interventional Procedures With a Risk-Based Analysis Approach. | LitMetric

Preventing Harm From Fluoroscopically Guided Interventional Procedures With a Risk-Based Analysis Approach.

J Am Coll Radiol

VA National Center for Patient Safety, Ann Arbor, Michigan; Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan and VA National Center for Patient Safety, Ann Arbor, Michigan. Electronic address:

Published: September 2019

Purpose: Fluoroscopically guided interventional (FGI) procedures often have lower complication rates compared with alternative surgical procedures, providing an option for patients with a high risk of perioperative mortality. Although severe radiation injuries are rare, patients receiving peak skin doses exceeding 3 Gy can suffer from radiation-induced tissue injuries, ranging from transient erythema to nonhealing wounds. As these iatrogenic injuries may manifest weeks to months postprocedure, proper diagnosis and timely medical intervention are less likely. Clinically, the lack of situational awareness for monitoring air kerma continues to be a challenge despite the recommendations of numerous organizations on ways to achieve fluoroscopy safety. For patient safety efforts, this study aimed to identify and mitigate systematic gaps associated with potentially high-radiation dose fluoroscopic procedures in US Department of Veterans Affairs (VA) and non-VA medical institutions.

Methods: In this study, a multi-institutional team utilized Healthcare Failure Mode and Effect Analysis (HFMEA) on an example implantable cardioverter defibrillator lead extraction procedure.

Results: With this approach, 29 interventions were devised and prioritized by feasibility, cost-effectiveness, and expected clinical impact. Five of the 29 interventions were recommended for immediate implementation or piloting.

Conclusions: This work demonstrates the application of formal risk-based analysis techniques in FGI procedures. These high priority interventions may be valuable for other facilities to consider when performing potentially high-radiation dose procedures and conducting risk-benefit analyses. Formal risk analysis techniques such as the HFMEA process are recommended for other facilities to use to improve safety for their high-risk procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacr.2019.02.047DOI Listing

Publication Analysis

Top Keywords

fluoroscopically guided
8
guided interventional
8
risk-based analysis
8
fgi procedures
8
high-radiation dose
8
analysis techniques
8
procedures
7
preventing harm
4
harm fluoroscopically
4
interventional procedures
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!