A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prostatic Artery Embolization for Benign Prostatic Hyperplasia: Prospective Randomized Trial of 100-300 μm versus 300-500 μm versus 100- to 300-μm + 300- to 500-μm Embospheres. | LitMetric

Prostatic Artery Embolization for Benign Prostatic Hyperplasia: Prospective Randomized Trial of 100-300 μm versus 300-500 μm versus 100- to 300-μm + 300- to 500-μm Embospheres.

J Vasc Interv Radiol

Department of Interventional Radiology, Hospital Saint Louis, Rua Luz Soriano No. 182, 1200-249, Lisbon, Portugal; Department of Radiology, NOVA Medical School, Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Lisbon, Portugal. Electronic address:

Published: May 2019

Purpose: This study compared the safety and efficacy of prostatic arterial embolization (PAE) with that of trisacryl gelatin microspheres of different sizes for treatment of benign prostatic hyperplasia (BPH).

Materials And Methods: This study consisted of a single-center, randomized controlled clinical trial in 138 patients who underwent PAE for BPH between July 2015 and December 2016. Patients were randomized to PAE using microspheres of different sizes: group A patients were treated with microspheres 100-300 μm, group B with 300-500 μm, and group C with 100-300 μm followed by 300-500 μm. All patients were evaluated before and at 1, 3, 6, 12, and 18 months after PAE. Baseline data were comparable across the 3 groups, using the following mean International Prostate Symptom Score/quality of life (IPSS/QoL); prostate volume (PV) scores, respectively: 23.0/4.14; 87.9 cm (group A); 23.0/4.09; 89.0 cm (group B); and 24.2/4.29; 81.0 cm (group C) (P > 0.05).

Results: Mean IPSS/QoL scores; PV after PAE were: 9.98/2.49; 65.1 cm (group A); 8.24/2.26; 63.1 cm (group B); and 10.1/2.69; 53.1 cm (group C) (P = 0.23; P = 0.39; P = 0.24). There were 26 clinical failures. The cumulative probabilities of clinical success at 18 months were 76.7% in group A, 82.6% in group B, and 83.3% in group C (P = 0.68). Nontarget embolization was prevented in 6 patients by coil embolization. All adverse events were mild and self-limited with rates of 86.0% in group A (37 of 43); 41.3% in group B (19 of 46); and 58.3% in group C (28 of 48) (P < 0.001). Dysuria was the most frequent adverse event (28 of 137 [20.4%]).

Conclusions: PAE outcomes were not significantly different among microspheres of different sizes. The use of 100- to 300-μm microspheres was associated with an increased risk of minor adverse events.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2019.02.014DOI Listing

Publication Analysis

Top Keywords

group
15
100-300 μm
12
300-500 μm
12
microspheres sizes
12
benign prostatic
8
prostatic hyperplasia
8
μm versus
8
μm group
8
group p =
8
adverse events
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!