Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of this study was to support management of airborne bacteria in facilities used by pollution-sensitive individuals (in daycares, medical facilities, elder care facilities, and postnatal care centers). A field survey was conducted on 11 facilities from October 2017 to April 2018. Elder care facilities in industrial, urban, and forested areas were excluded. Two indoor, and one outdoor, measuring points were selected per facility. These points were located in areas most often used by the residents. Measurements were taken at random time-points before February 2018 and at specific times in the morning and afternoon thereafter. The relationships among bacterial counts, carbon dioxide concentrations, dust levels, temperature, relative humidity, and ventilation were examined. The pooled average bacterial counts at the daycares, medical facilities, elder care facilities, and postnatal care centers were 540.25 CFU m, 245.49 CFU m, 149.63 CFU m, and 169.65 CFU m, respectively. Considering the upper 95% confidence interval, the bacterial counts in many daycares may in fact be >800 CFU m, which is the threshold set by the Korean Ministry of the Environment. The pooled average indoor: outdoor bacterial count ratio was 1.13. Indoor airborne bacterial counts were influenced mainly by their sources. This study found no significant correlations among indoor temperature, relative humidity, carbon dioxide concentration, dust levels, and airborne bacterial counts, unlike previous studies. Airborne bacteria management at daycares should be a top priority. The sources of airborne bacteria must also be identified, and a management plan must be developed to control them.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6539986 | PMC |
http://dx.doi.org/10.3390/ijerph16091483 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!