Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To evaluate the effect of Cisplatin on bone repair and mineralization around implants and on the mechanical properties of bone tissue.
Materials And Methods: Forty-three Wistar rats were randomly divided into two groups: Cisplatin (CIS, medication) and control (CTL, placebo solution), administered once a week for 4 weeks. After 4 weeks, implants were installed in both tibiae metaphysis. After 30 and 60 days, the animals were sacrificed and their femurs and tibiae were removed. Femurs were subjected to mechanical tests and tibiae for removal torque, arrangement and distribution of collagen fibers, morphometrical analyses (bone tissue in contact with the implant surface [BIC] and areal fraction between implant threads occupied by bone tissue [BAFO]) and scanning electron microscopy to calcium and calcium/phosphorus analysis. Data were analyzed by ANOVA or MANOVA, and Tukey or Games-Howell post hoc tests, respectively (α = 0.05).
Results: The CTL specimens had significantly higher values (0.0001 ≤ p≤0.036) of strength (N), removal torque (N/cm ), %BIC, and %BAFO than CIS specimens, being their best results at day 60. No significant differences were found among the groups regarding the values of deformation, percentage of calcium, and calcium/phosphorus ratio. In CIS groups, there was a reduction in the organization of collagen at the bone/implant interface, resulting in a trabecular bone with thin trabeculae and birefringent collagen and irregular arrangement.
Conclusions And Clinical Implications: Cisplatin interfered negatively in the repair and mineralization around dental implants, as well as on the quality of the bone tissue, mainly in the period of 30 days after the implant placement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.13445 | DOI Listing |