Tidal volume challenge to predict fluid responsiveness in the operating room: An observational study.

Eur J Anaesthesiol

From the Department of Anaesthesia and Intensive Care Medicine, IRCCS Humanitas, Humanitas University, Milan (AM, MC), the Department of Anaesthesia and Intensive Care Medicine, Maggiore della Carità University Hospital, Novara (CM, GC, FG, LM, FDC), the Department of Anaesthesiology and Intensive Care, San Bortolo Hospital, Vicenza (SDR), and the Department of Anaesthesia and Intensive Care, Department of Medical and Surgical Sciences, Magna Graecia University, Catanzaro, Italy (PN).

Published: August 2019

Background: Pulse pressure variation (PPV) and stroke volume variation (SVV) do not predict fluid responsiveness when using a protective ventilation strategy: the use of functional haemodynamic tests can be useful to overcome this limitation.

Objectives: We tested the use of a tidal volume challenge (VTC), during 6 ml kg [predicted body weight (PBW)] ventilation, and the end-expiratory occlusion test (EEOT) for prediction of fluid responsiveness.

Design: An interventional prospective study.

Setting: Supine elective neurosurgical patients.

Interventions: The study protocol was, first, the initial EEOT test was performed during baseline 6 ml kg PBW ventilation; second, VTC was performed by increasing the VT up to 8 ml kg PBW and PPV and SVV changes were recorded after 1 min; third, a second EEOT was performed during 8 ml kg PBW ventilation; and VT was reduced back to 6 ml kg PBW and a third EEOT was performed. Finally, a 250 ml fluid challenge was administered over 10 min to identify fluid responders (increase in stroke volume index ≥10%).

Results: In the 40 patients analysed, PPV and SVV values at baseline and EEOT performed at 6 ml kg PBW did not predict fluid responsiveness. A 13.3% increase in PPV after VTC predicted fluid responsiveness with a sensitivity of 94.7% and a specificity of 76.1%, while a 12.1% increase in SVV after VTC predicted fluid responsiveness with a sensitivity of 78.9% and a specificity of 95.2%. After EEOT performed at 8 ml kg PBW, a 3.6% increase in cardiac index predicted fluid responsiveness with a sensitivity of 89.4% and a specificity of 85.7%, while a 4.7% increase in stroke volume index (SVI) with a sensitivity of 89.4% and a specificity of 85.7%.

Conclusion: The changes in PPV and SVV obtained after VTC are reliable and comparable to the changes in CI and SVI obtained after EEOT performed at 8 ml kg PBW in predicting fluid responsiveness in neurosurgical patients.

Trial Registration: ACTRN12618000351213.

Download full-text PDF

Source
http://dx.doi.org/10.1097/EJA.0000000000000998DOI Listing

Publication Analysis

Top Keywords

fluid responsiveness
28
eeot performed
20
8 ml kg pbw
16
predict fluid
12
stroke volume
12
6 ml kg pbw
12
ppv svv
12
performed 8 ml kg
12
predicted fluid
12
responsiveness sensitivity
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!