Unlabelled: Purpose Video see-through augmented reality (VST-AR) navigation for laparoscopic partial nephrectomy (LPN) can enhance intraoperative perception of surgeons by visualizing surgical targets and critical structures of the kidney tissue. Image registration is the main challenge in the procedure. Existing registration methods in laparoscopic navigation systems suffer from limitations such as manual alignment, invasive external marker fixation, relying on external tracking devices with bulky tracking sensors and lack of deformation compensation. To address these issues, we present a markerless automatic deformable registration framework for LPN VST-AR navigation.

Method: Dense stereo matching and 3D reconstruction, automatic segmentation and surface stitching are combined to obtain a larger dense intraoperative point cloud of the renal surface. A coarse-to-fine deformable registration is performed to achieve a precise automatic registration between the intraoperative point cloud and the preoperative model using the iterative closest point algorithm followed by the coherent point drift algorithm. Kidney phantom experiments and in vivo experiments were performed to evaluate the accuracy and effectiveness of our approach.

Results: The average segmentation accuracy rate of the automatic segmentation was 94.9%. The mean target registration error of the phantom experiments was found to be 1.28 ± 0.68 mm (root mean square error). In vivo experiments showed that tumor location was identified successfully by superimposing the tumor model on the laparoscopic view.

Conclusion: Experimental results have demonstrated that the proposed framework could accurately overlay comprehensive preoperative models on deformable soft organs automatically in a manner of VST-AR without using extra intraoperative imaging modalities and external tracking devices, as well as its potential clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11548-019-01974-6DOI Listing

Publication Analysis

Top Keywords

deformable registration
12
markerless automatic
8
automatic deformable
8
registration framework
8
augmented reality
8
partial nephrectomy
8
external tracking
8
tracking devices
8
automatic segmentation
8
intraoperative point
8

Similar Publications

Purpose: Bone expansion is one of the quickest, simplest, and most reliable methods of alveolar ridge augmentation for implant placement. This systematic review is designed to investigate the outcomes of the bone expansion technique for horizontal ridge augmentation.

Methods: The protocol of study has been prospectively registered into PROSPERO (CRD42023414686).

View Article and Find Full Text PDF

Introduction: A chest X-ray (CXR) is the most common imaging investigation performed worldwide. Advances in machine learning and computer vision technologies have led to the development of several artificial intelligence (AI) tools to detect abnormalities on CXRs, which may expand diagnostic support to a wider field of health professionals. There is a paucity of evidence on the impact of AI algorithms in assisting healthcare professionals (other than radiologists) who regularly review CXR images in their daily practice.

View Article and Find Full Text PDF

Introduction: Alleviating postoperative pain from developmental dysplasia of the hip (DDH) surgery is beneficial for paediatric patients. The most commonly used anaesthetic approach currently is general anaesthesia combined with regional nerve blocks. Existing research primarily focuses on studies comparing regional nerve blocks with placebo controls, or studies comparing two different regional nerve blocking techniques.

View Article and Find Full Text PDF

Introduction: The megalencephaly capillary malformation polymicrogyria (MCAP syndrome) results from mosaic gain-of-function variants. The main clinical features are macrocephaly, somatic overgrowth, neurodevelopmental delay and brain anomalies. Alpelisib (Vijoice) is a recently FDA-approved PI3Kα-specific inhibitor for patients with PIK3CA-related overgrowth spectrum (PROS).

View Article and Find Full Text PDF

Background: Diabetic myocardial disorder (DbMD, evidenced by abnormal echocardiography or cardiac biomarkers) is a form of stage B heart failure (SBHF) at high risk for progression to overt HF. SBHF is defined by abnormal LV morphology and function and/or abnormal cardiac biomarker concentrations.

Objective: To compare the evolution of four DbMD groups based on biomarkers alone, systolic and diastolic dysfunction alone, or their combination.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!