Hyperspectral imaging (HSI) enables visualisation of morphological and biochemical information, which could improve disease diagnostic accuracy. Unfortunately, the wide range of image distortions that arise during flexible endoscopy in the clinic have made integration of HSI challenging. To address this challenge, we demonstrate a hyperspectral endoscope (HySE) that simultaneously records intrinsically co-registered hyperspectral and standard-of-care white light images, which allows image distortions to be compensated computationally and an accurate hyperspectral data cube to be reconstructed as the endoscope moves in the lumen. Evaluation of HySE performance shows excellent spatial, spectral and temporal resolution and high colour fidelity. Application of HySE enables: quantification of blood oxygenation levels in tissue mimicking phantoms; differentiation of spectral profiles from normal and pathological ex vivo human tissues; and recording of hyperspectral data under freehand motion within an intact ex vivo pig oesophagus model. HySE therefore shows potential for enabling HSI in clinical endoscopy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6478902 | PMC |
http://dx.doi.org/10.1038/s41467-019-09484-4 | DOI Listing |
Neuroimage
January 2025
School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing, 100191, China; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, 100191, Beijing, China; National Innovation Platform for industry-Education Integration in Medicine-Engineering Interdisciplinary, Shandong Key Laboratory for Magnetic Field-free Medicine and Functional Imaging, Shandong University, Research Institute of Shandong University, Jinan, 250014, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou, 310051, China; State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China; Hefei National Laboratory, Hefei, 230088, China. Electronic address:
The optically pumped magnetometer (OPM) based magnetoencephalography (MEG) system offers advantages such as flexible layout and wearability. However, the position instability or jitter of OPM sensors can result in bad channels and segments, which significantly impede subsequent preprocessing and analysis. Most common methods directly reject or interpolate to repair these bad channels and segments.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Geomatics, National Cheng Kung University, No. 1, University Rd., Tainan 701, Taiwan.
With the rapid development of the autonomous vehicles industry, there has been a dramatic proliferation of research concerned with related works, where road markings detection is an important issue. When there is no public open data in a field, we must collect road markings data and label them by ourselves manually, which is huge labor work and takes lots of time. Moreover, object detection often encounters the problem of small object detection.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Postgraduate Program in Biotechnology, Parnaíba Delta Federal University, Parnaíba 64202-020, Brazil.
Human Pose Estimation (HPE) is a computer vision application that utilizes deep learning techniques to precisely locate Key Joint Points (KJPs), enabling the accurate description of a person's pose. HPE models can be extended to facilitate Range of Motion (ROM) assessment by leveraging patient photographs. This study aims to evaluate and compare the performance of HPE models for assessing upper limbs ROM.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Institute of Communication Systems, Faculty of Electronics, Military University of Technology, 00-908 Warsaw, Poland.
Image reconnaissance systems are critical in modern applications, where the ability to accurately detect and identify objects is crucial. However, distortions in real-world operational conditions, such as motion blur, noise, and compression artifacts, often degrade image quality, affecting the performance of detection systems. This study analyzed the impact of super-resolution (SR) technology, in particular, the Real-ESRGAN model, on the performance of a detection model under disturbed conditions.
View Article and Find Full Text PDFLife (Basel)
November 2024
Department of Electronic Engineering, National Taipei University of Technology, Taipei 10608, Taiwan.
After a fracture, patients have reduced willingness to bend and extend their elbow joint due to pain, resulting in muscle atrophy, contracture, and stiffness around the elbow. Moreover, this may lead to progressive atrophy of the muscles around the elbow, resulting in permanent functional loss. Currently, a goniometer is used to measure the range of motion, ROM, to evaluate the recovery of the affected limb.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!