Background: Endotracheal tubes with standard polyvinyl chloride cuffs create folds on inflation into the trachea, which lead to potential leakage of subglottic secretions into the lower airways and cause lung colonization and pneumonia. The use of a double-layer prototype leak-proof cuff has shown effective prevention of the fluid leakage across the cuff. We hypothesized that the use of such a leak-proof cuff could prevent lung bacterial colonization in vivo.

Methods: To simulate patients in the ICU, 13 pigs were placed in the semirecumbent position, intubated, and mechanically ventilated for 72 h. Five animals were prospectively intubated with an endotracheal tube with a leak-proof cuff (leak-proof cuff group). Data from 8 animals previously intubated with an endotracheal tube with a standard polyvinyl chloride cuff (standard cuff group) were retrospectively analyzed. Leakage of tracheal secretions across the leak-proof cuff was tested by the macroscopic methylene blue evaluation. Arterial blood gas exchanges and microbiology were tested in all the pigs at necropsy.

Results: In the standard cuff group, all the pigs showed heavy bacterial colonization of the lungs after 72 h of mechanical ventilation, with an overall proportion of colonized lung lobes of 92% (44/48 lobes, 8/8 animals) compared with 27% (8/30 lobes, 5/5 animals) in the leak-proof cuff group ( < .001). These results were strengthened by the absence of methylene blue in the tracheal secretions below the leak-proof cuff. Furthermore, no hypoxemia was demonstrated in the pigs in the leak-proof cuff group after the 72-h experiment (P /F change from baseline, leak-proof cuff group vs standard cuff group; median difference 332, 95% CI 41-389 mm Hg; = .030).

Conclusions: A new leak-proof cuff for endotracheal intubation prevented macroscopic leakage of subglottic secretions along the airways. This mechanism led to the reduction of lung bacterial colonization, which could contribute to the prevention of hypoxemia in the pigs on mechanical ventilation while in the semirecumbent position.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6818682PMC
http://dx.doi.org/10.4187/respcare.06573DOI Listing

Publication Analysis

Top Keywords

leak-proof cuff
40
cuff group
28
bacterial colonization
16
cuff
16
lung bacterial
12
endotracheal tube
12
standard cuff
12
leak-proof
11
standard polyvinyl
8
polyvinyl chloride
8

Similar Publications

Article Synopsis
  • The video outlines a 5-step surgical technique for safely removing large ovarian cysts through a single-port laparoscopic incision, which is less invasive than traditional large incisions.* -
  • The technique involves diagnostic laparoscopy, applying a glove/membrane for fluid containment, and carefully aspirating cystic fluid to maintain oncological safety.* -
  • This approach allows for quicker recovery and reduced risk of abdominal contamination compared to conventional methods, making it a valuable option in managing ovarian masses.*
View Article and Find Full Text PDF

Background: Endotracheal tubes with standard polyvinyl chloride cuffs create folds on inflation into the trachea, which lead to potential leakage of subglottic secretions into the lower airways and cause lung colonization and pneumonia. The use of a double-layer prototype leak-proof cuff has shown effective prevention of the fluid leakage across the cuff. We hypothesized that the use of such a leak-proof cuff could prevent lung bacterial colonization in vivo.

View Article and Find Full Text PDF

Long-term patient comfort after an ileal conduit urinary diversion depends on the conduit stoma. The problem of leak-proof urine collection of the flush stoma can be overcome by using a spout stoma but this could become stenotic unless everted. Eversion is a technically difficult procedure and produces a bulky spout that tends to prolapse.

View Article and Find Full Text PDF

The current study was designed to test the value of oesophageal muscular cuffs in the repair of anastomotic defects in the thoracic oesophagus. In 30 piglets, defects involving 25%, 50% and nearly 100% of the anastomosis were created and repaired by means of a cuff derived from the oesophagus musculature. The results demonstrated that his method provides uniformly a leak-proof closure under the most severe circumstances.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!