A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

QMRA of adenovirus in drinking water at a drinking water treatment plant using UV and chlorine dioxide disinfection. | LitMetric

According to the Dutch Drinking Water Act of 2011, Dutch drinking water suppliers must conduct a Quantitative Microbial Risk Assessment (QMRA) for infection by the following index pathogens: enterovirus, Campylobacter, Cryptosporidium and Giardia at least once every four years in order to assess the microbial safety of drinking water. The health-based target for safe drinking water is set at less than one infection per 10 000 persons per year. At Evides Water Company, concern has arisen whether their drinking water treatment, mainly based on UV inactivation and chlorine dioxide, reduces levels of adenovirus (AdV) sufficiently. The main objective was, therefore, to conduct a QMRA for AdV. Estimates of the AdV concentrations in source water were based on enumeration of total AdV by integrated cell culture PCR (iccPCR), most probable number PCR (mpnPCR) and quantitative PCR (qPCR), and on enumeration of AdV40/41 by mpnPCR and qPCR. AdV40/41 represents a large fraction of total AdV and only a small fraction of AdV is infectious (1/1700). By comparison of literature data and plant scale data, somatic coliphages appeared a good, conservative indicator for AdV disinfection by UV irradiation. Similarly, bacteriophage MS2 appeared to be a good, conservative indicator for disinfection by chlorine dioxide. Literature data on the efficiency of chlorine dioxide disinfection were fitted with the extended HOM model. Chlorine dioxide disinfection at low initial concentrations (0.05-0.1 mg/l) was found to be the major treatment step, providing sufficient treatment on its own for compliance with the health-based target. UV disinfection of AdV at 40 mJ/cm or 73 mJ/cm was insufficient without chlorine dioxide disinfection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2019.03.090DOI Listing

Publication Analysis

Top Keywords

drinking water
28
chlorine dioxide
24
dioxide disinfection
16
water
9
water treatment
8
dutch drinking
8
health-based target
8
adv
8
total adv
8
literature data
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!