Aims: The aim of this study was to investigate the prognostic value of fractional flow reserve (FFR) and a novel index (the D-index) of residual diffuse disease after intravascular ultrasound (IVUS)-guided second-generation drug-eluting stent (DES) implantation.
Methods And Results: We evaluated 201 patients (201 lesions) who underwent IVUS-guided second-generation DES implantation in the left anterior descending artery with pre- and post-intervention physiological evaluations. Post-intervention hyperaemic pullback pressure recording was used to quantify residual diffuse disease using the novel D-index, defined as the difference between the distal stent and the far distal FFR values divided by distance. Clinical outcomes were assessed by vessel-oriented composite endpoints (VOCE) and major adverse cardiac events (MACE). The incremental discriminant and reclassification abilities of far distal FFR or D-index for VOCE and MACE were compared. Post intervention, far distal FFR and D-indices were significantly lower in vessels with VOCE. The optimal far distal FFR and D-index cut-off values for VOCE and MACE were 0.86 and 0.017 cm, respectively. Although both indices remained significant predictors of VOCE, only the D-index proved to be a significant predictor of MACE and significantly improved the incremental reclassification ability for MACE.
Conclusions: Residual diffuse disease assessed by the D-index after IVUS-guided second-generation DES implantation can help to predict both VOCE and MACE, while far distal FFR can help to predict VOCE specifically.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4244/EIJ-D-18-01032 | DOI Listing |
Radiol Adv
October 2024
Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).
Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.
Int J Cardiovasc Imaging
January 2025
Departments of Cardiology, Amsterdam Cardiovascular Sciences, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
The introduction of wire-free microcirculatory resistance index from functional angiography (angio-IMR) promises swift detection of coronary microvascular dysfunction, however it has not been properly validated. We sought to validate angio-IMR against invasive IMR and PET derived microvascular resistance (MVR). Moreover, we studied if angio-IMR could aid in the detection of ischemia with non-obstructive coronary arteries (INOCA).
View Article and Find Full Text PDFJ Clin Med
November 2024
Department of Internal Medicine, National Taiwan University Hospital, Hsin-Chu Branch, Hsin-Chu 300195, Taiwan.
Eur Heart J Imaging Methods Pract
July 2024
Clinic of Cardiology, St. Olavs University Hospital, PO 3250 Torgarden, 7006 Trondheim, Norway.
Aims: This study aims to assess the diagnostic performance of a novel computed tomography-derived fractional flow reserve (CT-FFR) algorithm and to compare its accuracy at three predefined sites: (i) at the location of invasive FFR measurements (CT-FFR), (ii) at selected sites determined by an automated module integrated within the algorithm (CT-FFR), and (iii) distally in the vessel (CT-FFR).
Methods And Results: We prospectively recruited 108 consecutive patients with stable symptoms of coronary artery disease and at least one suspected obstructive lesion on coronary computed tomography angiography (CCTA). CT-FFR was validated against invasive FFR as gold standard using FFR ≤ 0.
Int J Cardiol
January 2025
Department of Cardiology, Amsterdam UMC - Location AMC, Amsterdam, the Netherlands.