AI Article Synopsis

Article Abstract

Aims: The aim of this study was to investigate the prognostic value of fractional flow reserve (FFR) and a novel index (the D-index) of residual diffuse disease after intravascular ultrasound (IVUS)-guided second-generation drug-eluting stent (DES) implantation.

Methods And Results: We evaluated 201 patients (201 lesions) who underwent IVUS-guided second-generation DES implantation in the left anterior descending artery with pre- and post-intervention physiological evaluations. Post-intervention hyperaemic pullback pressure recording was used to quantify residual diffuse disease using the novel D-index, defined as the difference between the distal stent and the far distal FFR values divided by distance. Clinical outcomes were assessed by vessel-oriented composite endpoints (VOCE) and major adverse cardiac events (MACE). The incremental discriminant and reclassification abilities of far distal FFR or D-index for VOCE and MACE were compared. Post intervention, far distal FFR and D-indices were significantly lower in vessels with VOCE. The optimal far distal FFR and D-index cut-off values for VOCE and MACE were 0.86 and 0.017 cm, respectively. Although both indices remained significant predictors of VOCE, only the D-index proved to be a significant predictor of MACE and significantly improved the incremental reclassification ability for MACE.

Conclusions: Residual diffuse disease assessed by the D-index after IVUS-guided second-generation DES implantation can help to predict both VOCE and MACE, while far distal FFR can help to predict VOCE specifically.

Download full-text PDF

Source
http://dx.doi.org/10.4244/EIJ-D-18-01032DOI Listing

Publication Analysis

Top Keywords

distal ffr
20
residual diffuse
12
diffuse disease
12
ivus-guided second-generation
12
voce mace
12
fractional flow
8
flow reserve
8
second-generation drug-eluting
8
novel d-index
8
second-generation des
8

Similar Publications

Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).

Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.

View Article and Find Full Text PDF

The introduction of wire-free microcirculatory resistance index from functional angiography (angio-IMR) promises swift detection of coronary microvascular dysfunction, however it has not been properly validated. We sought to validate angio-IMR against invasive IMR and PET derived microvascular resistance (MVR). Moreover, we studied if angio-IMR could aid in the detection of ischemia with non-obstructive coronary arteries (INOCA).

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates how well the drop in coronary pressure after administering nitroglycerin (NTG) can predict fractional flow reserve (FFR) compared to the resting full-cycle ratio (RFR).
  • In total, 202 vessels were analyzed from two prospective studies, where NTG-Pd/Pa showed a strong correlation with FFR (r = 0.945) and a cutoff value of 0.85 was established.
  • Results indicated that NTG-Pd/Pa performed better than RFR in predicting FFR ≤ 0.8, with higher accuracy (91% vs. 84%) and sensitivity, making it a potentially more effective diagnostic tool.
View Article and Find Full Text PDF

Aims: This study aims to assess the diagnostic performance of a novel computed tomography-derived fractional flow reserve (CT-FFR) algorithm and to compare its accuracy at three predefined sites: (i) at the location of invasive FFR measurements (CT-FFR), (ii) at selected sites determined by an automated module integrated within the algorithm (CT-FFR), and (iii) distally in the vessel (CT-FFR).

Methods And Results: We prospectively recruited 108 consecutive patients with stable symptoms of coronary artery disease and at least one suspected obstructive lesion on coronary computed tomography angiography (CCTA). CT-FFR was validated against invasive FFR as gold standard using FFR ≤ 0.

View Article and Find Full Text PDF
Article Synopsis
  • In patients with angina but no major coronary blockages (ANOCA), researchers investigated whether measuring hyperaemic microvascular resistance (HMR) using aortic pressure (Pa) is as effective as using distal pressure (Pd).
  • Analysis of data from the ILIAS registry showed a strong correlation between HMR calculated with Pa and Pd, especially in patients with functional epicardial lesions rated as non-severe (FFR >0.80).
  • The study concluded that while HMR can be accurately determined using aortic pressure in patients with non-severe lesions, significant discrepancies occur when measuring in patients with more severe lesions (FFR <0.80).
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!