A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a point-of-contact technique to measure adenosine triphosphate: A quality improvement study. | LitMetric

Development of a point-of-contact technique to measure adenosine triphosphate: A quality improvement study.

Ann Med Surg (Lond)

University of Kansas Medical Center, School of Nursing, Mail Stop 4043, 3901 Rainbow Blvd, Kansas City, KS, 66160, USA.

Published: May 2019

Purpose: Patients with heart failure with preserved ejection fraction (HFpEF) experience fatigue due to impaired myocardial bioenergetics. Cardiomyocyte function depends on the delivery of adenosine triphosphate (ATP), yet there is no convenient bedside method to measure ATP. The purpose of this study was to develop a point-of-contact measurement of ATP that can be used in a clinical setting.

Methods: In a laboratory setting, digital finger punctures were conducted using 5 μl and 10 μl of capillary blood placed into various amounts of water (H2O). After mixing the solution for 10 s, a Hygiena AquaSnapTM Free ATP probe was placed into the solution for 10 s for the detection of ATP. The probe was then placed into the Hygiena luminometer for 15 s, and a value in relative light units (RLU) was obtained.

Results: Test samples using 10 μl of blood diluted from 50 to 500 mls of H2O produced ATP readings of 10,000-7569 RLUs. Using 5 μl of blood in 375-900 ml of H2O decreased the ATP values to 6459-4189 RLUs. Dilutional volume sparing experiments were conducted with ATP standards to determine the concentration of ATP per RLUs.

Conclusion: Patients with HFpEF have increased metabolic demand and impaired myocardial bioenergetics. Thus, identifying a method to measure ATP that is quick and accurate is imperative to accurately assess cellular energy production in this population. Point-of-contact measures, such as ATP, are needed for precision-guided treatment. Data from this study provides the first step toward developing evidence for health policies related to managing fatigue.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6462498PMC
http://dx.doi.org/10.1016/j.amsu.2019.03.013DOI Listing

Publication Analysis

Top Keywords

atp
11
adenosine triphosphate
8
impaired myocardial
8
myocardial bioenergetics
8
method measure
8
measure atp
8
solution 10 s
8
atp probe
8
development point-of-contact
4
point-of-contact technique
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!