A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Nonmodular Stems Are a Viable Alternative to Modular Stems in Revision Total Hip Arthroplasty. | LitMetric

Background: Nonmodular and modular femoral stems have been associated with complications after revision total hip arthroplasty (rTHA). As such, the ideal femoral component for rTHA remains undecided. This study aims to report outcomes of titanium, tapered-fluted, modular and nonmodular femoral components in rTHA.

Methods: From January 1, 2013 to September 30, 2017, all rTHAs using modular or nonmodular femoral stems were identified. Demographic data including age, gender, and American Society of Anesthesiologists scores were collected. Surgical details including operative time and implant cost were also collected. Clinical outcomes including length of stay, dislocation, infection, fracture, reoperation, and re-revision were collected. Statistical analysis was performed using chi-square test and Student's t-test for all categorical and continuous variables, respectively.

Results: One hundred forty-six rTHA cases (103 modular and 43 nonmodular) were identified with an average follow-up of 29 months (range 3-59 months). Nonmodular stems had a significantly lower cost when compared to modular implants (modular stems 120.8% higher cost; P < .001). The surgical time of nonmodular components was significantly greater (193 minutes vs 163 minutes; P = .029). There were no differences observed in any other surgical details or clinical outcomes assessed, including length of stay (P = .323), rate of re-revision of the femoral implant (P = .389), rate of re-operation (P = .383), and postop complications (P = .241), including infection (P = .095), dislocation (P = .778), and fracture (P = .959).

Conclusions: Nonmodular components provide encouraging clinical results with significantly lower costs compared to modular implants in rTHA. The use of titanium, tapered-fluted, nonmodular components may offer a more cost-effective approach to rTHA compared to their modular counterparts.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2019.03.007DOI Listing

Publication Analysis

Top Keywords

modular nonmodular
12
compared modular
12
nonmodular components
12
nonmodular
9
modular
9
nonmodular stems
8
modular stems
8
revision total
8
total hip
8
hip arthroplasty
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!