Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The introduction of video laryngoscopy (VL) may impact emergency medicine (EM) residents' intubation practices.
Methods: We analyzed 14,313 intubations from 11 EM training sites, July 1, 2002, to December 31, 2012, assessing the likelihood of first-attempt success and likelihood of having a second attempt, by rank and device. We determined whether direct laryngoscopy (DL) first-attempt success decreased as VL became more prevalent using a logistic regression model with proportion of encounters initiated with VL at that center in the prior 90 and 365 days as predictors of DL first-attempt success.
Results: First-attempt success by PGY-1s was 71% (95% confidence interval [CI] = 63% to 78%); PGY-2s, 82% (95% CI = 78% to 86%); and PGY-3+, 89% (95% CI = 85% to 92%). Residents' first-attempt success rate was higher with the C-MAC video laryngoscope (C-MAC) versus DL, 92% versus 84% (risk difference [RD] = 8%, 95% CI = 4% to 11%), but there was no statistical difference between the GlideScope video laryngoscope (GVL) and DL, 80% versus 84% (RD = -4%, 95% CI = -10% to 1%). PGY-1s were more likely to have a second intubation attempt after first-attempt failure with VL versus DL: 32% versus 18% (RD = 14%, 95% CI = 5% to 23%). DL first-attempt success rates did not decrease as VL became more prevalent.
Conclusions: First-attempt success increases with training. Interns are more likely to have a second attempt when using VL. The C-MAC may be associated with increased first-attempt success for EM residents compared with DL or GVL. The increasing prevalence of VL is not accompanied by a decrease in DL success.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6457358 | PMC |
http://dx.doi.org/10.1002/aet2.10316 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!