A comparative study of standard facemask jet nebulization and high-flow nebulization in bronchiolitis.

Exp Lung Res

c Chemical Engineering Division, Department of Biotechnology and Food Science , Universidad de Burgos , Burgos , Spain.

Published: June 2020

The use of a nebulizer paired with high-flow nasal cannulas (HFNC) has been proposed for drug delivery in bronchiolitis. Particle size nebulized is a relevant factor determining the efficacy of the nebulization. We replicated in vitro the theoretical parameters most widely used in bronchiolitis and we compared the size of the droplet nebulized with a standard nebulizer and a nebulizer integrated into HFNC. We used laser diffraction to analyze the particle size nebulized (volume median diameter Dv50). The standard system was a jet nebulizer connected to a facemask with a flow rate of 8 L/min (JN). Three designs were used as nebulizers integrated into HFNC: a vibrating mesh nebulizer set 1) before (HFNC-BH) and 2) after (HFNC-AH) the humidifier, and 3) a jet nebulizer connected before the nasal cannula (HFNC-BNC). HFNC was used with neonatal (3-8 L/min) and infant cannulas (8-15 L/min). Droplet size was similar among the three drugs studied. A lower particle size was obtained when using the nebulization system integrated into HFNC compared to the standard nebulizer, regardless of the flow rate and the nasal cannula used when the position of the nebulizer was before the nasal cannula ( < 0.05): 6.89 µm (JN), 2.49 µm (HFNC-BNC 3 L/min), 2.59 µm (HFNC-BNC 5 L/min), 2.44 µm (HFNC-BNC 8 L/min), 3.22 µm (HFNC-BNC 10 L/min), 3.23 µm (HFNC-BNC 13 L/min), 3.16 µm (HFNC-BNC 15 L/min). The particle size was lower in HFNC-BF compared to the HFNC-AH using neonatal nasal cannula (3-8 L/min) ( < 0.05). The use of a nebulizer integrated with HFNC has shown promising results in an experimental scenario of bronchiolitis. The particle size achieved with the nebulizer placed before the humidifier is equivalent to the one obtained via conventional nebulization, and it is even smaller when the integrated nebulizer is placed before the nasal cannulas.

Download full-text PDF

Source
http://dx.doi.org/10.1080/01902148.2019.1599084DOI Listing

Publication Analysis

Top Keywords

particle size
12
integrated hfnc
12
nasal cannula
12
nebulizer
8
size nebulized
8
standard nebulizer
8
jet nebulizer
8
nebulizer connected
8
flow rate
8
hfnc
5

Similar Publications

The study of degradation behavior of electrocatalysts in an industrial context calls for rapid and efficient analysis methods. Optical methods like Raman spectroscopy fulfil these requirements and are thus predestined for this purpose. However, the iridium utilized in proton exchange membrane electrolysis (PEMEL) is Raman inactive in its metallic state.

View Article and Find Full Text PDF

Background: Nanosuspension has emerged as an effective, lucrative, and unequalled approach for efficiently elevating the dissolution and bioavailability of aqueous soluble drugs. Diverse challenges persist within this domain, demanding further comprehensive investigation and exploration.

Objective: This study aims to design, develop, optimise formulation and process variables, and characterise the stabilised aqueous dissolvable nanosuspension using chlorthalidone as a BCS class- IV drug.

View Article and Find Full Text PDF

As tailpipe emissions have decreased, there is a growing focus on the relative contribution of non-exhaust sources of vehicle emissions. Addressing these emissions is key to better evaluating and reducing vehicles' impact on air quality and public health. Tailoring solutions for different non-exhaust sources, including brake emissions, is essential for achieving sustainable mobility.

View Article and Find Full Text PDF

The current chemotherapy treatments for liver cancer have shown limited effectiveness. Therefore, there is an urgent need to develop new drugs to combat this disease more effectively. This study reports synthesis of cobalt oxide nanoparticles coated with glucose, and conjugated with Ellagic acid.

View Article and Find Full Text PDF

A constitutive model for coal gangue coarse-grained subgrade filler incorporating particle breakage.

Sci Rep

January 2025

Hunan Provincial Key Laboratory of Geotechnical Engineering for Stability Control and Health Monitoring, Hunan University of Science and Technology, Xiangtan, 411201, People's Republic of China.

The accumulation and discharge amount of coal gangue are substantial, occupying significant land resources over time. Utilizing coal gangue as subgrade filler can generate notable economic and social benefits. Coal gangue coarse-grained soil (CGSF) was used to conduct a series of large-scale vibration compaction tests and large-scale triaxial tests.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!