Leg electrical resistance predicts venous blood viscosity and hematocrit.

Clin Hemorheol Microcirc

U1046 INSERM, UMR 9214 CNRS «Physiopathologie & Médecine Expérimentale du Coeur et des Muscles - PHYMEDEXP», Unité d'Explorations Métaboliques (CERAMM), Université de Montpellier, Département de Physiologie Clinique, Hôpital Lapeyronie CHRU Montpellier, France.

Published: October 2019

 We previously reported that whole body bioelectrical impedance analysis (BIA) measurements are correlated to some hemorheologic factors, suggesting a relationship between viscosity factors and electric properties of flowing blood not only in vitro but also in vivo. Recently we reported that with segmental BIA (analyzing the body considered as composed of 5 cylinders) predictive equations for various determinants of blood viscosity were closer than for the wole body. Another widely used BIA technique uses leg-to-leg impedance measurements so that two cylinders (the two legs) are analyzed. We investigated whether impedance measured with this technique (Tanita TBF-300) is also a predictor of blood viscosity factors. From viscometric measurements performed on venous blood drawn in recreative athletes over the range of shear rates 1 to 6000 s-1 (RHEOMETRE Anton Paar CP 50-1), we found a correlation between leg-leg resistance at 50 kHz (Rx[50 kHz]) and blood viscosity at 1000 s-1 (η1000= 0.0051 Rx[50 kHz] + 1.3265; r = 0.521 p = 0.028 yielding a prediction of η1000 (Bland Altman plot: bias 0.05 [RANGE - 0.24; 0.34]. Neither plasma viscosity nor the red cell rheology index «k» of Quemada's model are correlated with Rx[50 kHz], but hematocrit (Hct) does (Hct (%) = 0.0217 Rx[50 kHz] + 33.783; r = 0.480 p = 0.044) yielding a prediction of Hct (Bland Altman plot: bias - 0.11, [range - 1.67; 1.45]. The discrepancy between actual and predicted Hct is also correlated with resistance at 50 kHz (r = 0.575 p = 0.031) as does the discrepancy between actual and predicted Hct/viscosity ratio (r = -0.651 p = 0.006). Therefore, as other previously studied methods, leg to leg BIA predicts viscosity, suggesting that blood rheology may influence the passage of an electric current in the legs.

Download full-text PDF

Source
http://dx.doi.org/10.3233/CH-199003DOI Listing

Publication Analysis

Top Keywords

blood viscosity
16
venous blood
8
viscosity factors
8
resistance 50 khz
8
yielding prediction
8
bland altman
8
altman plot
8
plot bias
8
discrepancy actual
8
actual predicted
8

Similar Publications

This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.

View Article and Find Full Text PDF

This study aimed to investigate the effects of laminarin (LA) and ferulic acid (FA) on the gelatinization, rheological properties, freeze-thaw stability, and digestibility of cassava starch (CS). The results indicated that LA increased the peak viscosity, trough viscosity, final viscosity, storage modulus, and loss modulus of CS, while decreasing the breakdown viscosity. Conversely, FA exerted opposite effects.

View Article and Find Full Text PDF

Stroke is the second leading cause of death worldwide, according to the latest report by the World Health Organization (WHO). Intracerebral hemorrhage comprises 20-25% of the stroke in the young, with incidence rates of three to six in 100,000 people per year. One of the most common and important causes of hemorrhagic stroke in the general population is hypertension.

View Article and Find Full Text PDF

Purpose: Red blood cells (RBCs) senescence and blood rheology during ultra-endurance running events appear to be impacted differently depending on the race distance. The physiological mechanisms underlying these differences are poorly understood.

Methods: We investigated the effects of three different ultra-trail running races performed in La Reunion Island (Mascareignes, "the 70 km", 70 km/4,000 m D+; Trail Du Bourbon, "the 100 km", 100 km/6,090 m D+; Diagonale des Fous, "the 170 km", 170 km/10,500 m D+) on RBC oxidative stress, RBC senescence and blood rheology in 66 finishers (18 "70 km", 24 "100 km", 24 "170 km").

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!