A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection threshold of non-contacting laser profilometry and influence of thermal variation on characterisation of early surface form and textural changes in natural human enamel. | LitMetric

Objectives: To determine the detection threshold of non-contacting laser profilometry (NCLP) measuring surface form and surface roughness change in natural human enamel in vitro, characterise how ambient scanning thermal variation affects NCLP measurement, and calculate bulk enamel loss in natural human enamel.

Methods: NCLP repeatability and reproducibility accuracy was determined by consecutively scanning natural human enamel samples with/without sample repositioning. Ambient thermal variation and NCLP sensor displacement over short (30 s), medium (20 min), and long (2 h) scanning periods were evaluated for their standard deviation. Natural human enamel specimens (n = 12) were eroded using citric acid (0.3% w/w pH3.2) for 5, 10, and 15 min and characterised using surface profilometry, tandem scanning confocal microscopy (TSM), and optical coherence tomography (OCT).

Results: Repeatability and reproducibility error of NCLP for surface form was 0.28 μm and 0.43 μm, and for surface roughness 0.07 μm and 0.08 μm. Ambient thermal variation resulted in NCLP sensor displacement of 0.56 μm and 1.05 μm over medium and long scanning periods. Wear scar depth (μm) was calculated between 0.72-1.61 at 5 min, 1.72-3.06 at 10 min, and 3.40-7.06 at 15 min. Mean (SD) surface roughness (μm) was 1.13 (0.13), 1.52 (0.23), 1.44 (0.19), and 1.43 (0.21) at baseline, 5, 10, and 15 min. Qualitative image analysis indicated erosive change at the surface level, progressing after increasing erosion time.

Significance: Minimum detectable limits for NCLP measuring surface form and surface roughness changes were characterised. Ambient thermal variation, subsequent sensor displacement, and its impact on NCLP performance were characterised. Dental erosion lesions in natural human enamel could be characterised using surface profilometry, surface roughness, OCT, and TSM. Step height formation could be calculated within NCLP and temperature operating limits using profile superimposition and profile subtraction techniques. Natural enamel samples can now be used in in-vitro studies to investigate the formation and development of early acid erosive tooth wear, as well as the assessment of methods for enamel lesion remineralisation and repair.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2019.04.003DOI Listing

Publication Analysis

Top Keywords

natural human
24
thermal variation
20
human enamel
20
surface roughness
20
surface form
16
surface
12
variation nclp
12
ambient thermal
12
sensor displacement
12
nclp
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!