Large cortical bone pores in the tibia are associated with proximal femur strength.

PLoS One

Berlin-Brandenburg Center for Regenerative Therapies, Charité -Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.

Published: January 2020

Alterations of structure and density of cortical bone are associated with fragility fractures and can be assessed in vivo in humans at the tibia. Bone remodeling deficits in aging women have been recently linked to an increase in size of cortical pores. In this ex vivo study, we characterized the cortical microarchitecture of 19 tibiae from human donors (aged 69 to 94 years) to address, whether this can reflect impairments of the mechanical competence of the proximal femur, i.e., a major fracture site in osteoporosis. Scanning acoustic microscopy (12 μm pixel size) provided reference microstructural measurements at the left tibia, while the bone vBMD at this site was obtained using microcomputed tomography (microCT). The areal bone mineral density of both left and right femoral necks (aBMDneck) was measured by dual-energy X-ray absorptiometry (DXA), while homogenized nonlinear finite element models based on high-resolution peripheral quantitative computed tomography provided hip stiffness and strength for one-legged standing and sideways falling loads. Hip strength was associated with aBMDneck (r = 0.74 to 0.78), with tibial cortical thickness (r = 0.81) and with measurements of the tibial cross-sectional geometry (r = 0.48 to 0.73) of the same leg. Tibial vBMD was associated with hip strength only for standing loads (r = 0.59 to 0.65). Cortical porosity (Ct.Po) of the tibia was not associated with any of the femoral parameters. However, the proportion of Ct.Po attributable to large pores (diameter > 100 μm) was associated with hip strength in both standing (r = -0.61) and falling (r = 0.48) conditions. When added to aBMDneck, the prevalence of large pores could explain up to 17% of the femur ultimate force. In conclusion, microstructural characteristics of the tibia reflect hip strength as well as femoral DXA, but it remains to be tested whether such properties can be measured in vivo.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6469812PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0215405PLOS

Publication Analysis

Top Keywords

hip strength
16
cortical bone
8
tibia associated
8
proximal femur
8
tibia bone
8
associated hip
8
strength standing
8
large pores
8
associated
6
strength
6

Similar Publications

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF

Hip Adduction and Abduction Strength Reference Values of Gaelic Football and Rugby Union Players: A Cross-Sectional Study.

Int J Sports Physiol Perform

December 2024

Department of Orthopedic Surgery, Sports Orthopedic Research Center Copenhagen (SORC-C), Amager-Hvidovre Hospital, Institute of Clinical Medicine, Copenhagen University, Hvidovre, Denmark.

Purpose: The purpose of this research was to report isometric hip adduction and abduction strength reference values of men's and women's Gaelic football and rugby union players and compare values between sexes and between sports.

Methods: This cross-sectional cohort study consisted of 331 club-level athletes. Maximum isometric hip adduction squeeze and abduction press strength values were measured with a ForceFrame across several testing positions.

View Article and Find Full Text PDF

Innovative equipment for lower limb muscle strength measurement: Design and application in sarcopenia screening.

Clin Biomech (Bristol)

December 2024

Department of Geriatrics, West China Hospital, Sichuan University, Chengdu 610041, Sichuan, China.

Background: Grip Strength has been established as a practical and efficient method for screening and diagnosing sarcopenia. It is recognized that with advancing age, there is a more significant decline in lower limb muscle mass compared to the upper limb. However, due to the inherent complexity of assessing lower limb muscle strength compared to measuring Grip Strength, these assessments have not been universally adopted for sarcopenia screening.

View Article and Find Full Text PDF

Effect of a high-impact exercise program on hip strength indices in a group of obese women after bariatric surgery.

J Clin Densitom

December 2024

Department of Physical Education, Faculty of Arts and Sciences, University of Balamand, PO Box 100, Tripoli, Lebanon. Electronic address:

The purpose of this study was to explore the influence of a 12-month high-impact physical training program (descending stairs) on bone health in a group of young obese women who had undergone bariatric surgery (type sleeve). Fifty-two premenopausal women with a body mass index (BMI) > 35 kg/m (range: 35.06-60.

View Article and Find Full Text PDF

Objective: This study aimed to examine the relationship between pain catastrophizing (PC) and health-related quality of life (HRQoL), while accounting for pain intensity and other factors in patients with hip osteoarthritis (OA).

Methods: This multicenter, cross-sectional study included a total of 160 participants and was conducted at five hospitals in Japan. The primary outcome was the HRQoL status, which was assessed using the Japanese version of the 12-item Short Form.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!