A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Preparation of chitosan-Cu/NH physical hydrogel and its properties. | LitMetric

Preparation of chitosan-Cu/NH physical hydrogel and its properties.

Int J Biol Macromol

School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, PR China.

Published: July 2019

Chitosan (CTS) physical hydrogels crosslinked under gaseous ammonia atmospheres have attracted considerable attentions for their abilities to maximize the biological activities of CTS while maintaining their biocompatibility. However, poor mechanical properties significantly limit their application. The CTS-metal ion complexing hydrogels showed better mechanical properties. However, the formation process is uncontrollable, and the high dosages of metal ions used may cause cytotoxicity. In the present work, CTS-Cu/NH physical hydrogel with excellent comprehensive properties was prepared by ammonia fumigation and metal ion complexation. Its formation mechanism and structure were investigated. The above physical hydrogel revealed excellent mechanical properties with the mechanical strength up to 0.30 MPa, significantly higher than CTS/NH hydrogel, even at much lower Cu contents. And CTS-Cu/NH hydrogel is more thermal stable than CTS/NH hydrogel. In addition, it exhibited specific killing effects on Pseudomonas aeruginosa. These results suggest that CTS-Cu/NH physical hydrogel has a great application potential as a wound dressing.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijbiomac.2019.03.011DOI Listing

Publication Analysis

Top Keywords

physical hydrogel
16
mechanical properties
12
cts-cu/nh physical
8
cts/nh hydrogel
8
hydrogel
7
physical
5
properties
5
preparation chitosan-cu/nh
4
chitosan-cu/nh physical
4
hydrogel properties
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!