Research involving B-mode ultrasound imaging often requires user defined regions of interest (ROIs) for analysis, traditionally drawn/selected by a trained operator. This manual process is incredibly time consuming and subjective. Here, we propose a fast and simple method of detecting the average location of aponeurosis layers in ultrasound images of the upper trapezius to place a rectangular ROI for quantitative image analysis. A total of 56 B-mode ultrasound images were analyzed, where rectangular ROIs were manually placed in the skeletal muscle by two trained operators. Interoperator agreement was determined between the ROI border locations using intercorrelation coefficient (ICC). Next, our automatic algorithm was applied (image thresholding, binary masking, and pixel intensity peak detection), estimating the mean position of both aponeurosis layers for rectangular ROI placement. The automatic estimation method was compared with the manual (visual) method by various statistics ( t test, linear correlation, Bland-Altman plot). The performance was also evaluated under additive noise conditions (Speckle). Finally, agreement of the overlapping ROI area between the manual and automatic methods was also computed. Performance of the automatic method compared with manual placement was excellent for both the superficial and deep ROI borders, performing consistently even with additive noise (error <0.674 ± 1.69 mm). Manual measurements indicated excellent consensus (ICC = 0.902) between operators. The overlapping area between the manual and automatic measurements demonstrated good agreement (90.65 ± 11.3%). With constraints, our method is robust even under large levels of noise addition making the automatic algorithm an acceptable replacement for manual ROI placement in the upper trapezius.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0161734619839980 | DOI Listing |
J Ultrasound Med
January 2025
Department of Radiodiagnosis, Government Medical College and Hospital, Chandigarh, India.
Objectives: To determine the efficacy of quantitative shear wave elastography in differentiating benign and malignant axillary lymph nodes (ALN).
Methods: Exactly 127 lymph nodes from 127 patients with clinically palpable axillary swelling were examined by both B-mode sonography and elastography from November 2022 to March 2024. Gray-scale sonograms were evaluated based on: the short-axis diameter, shape, hilum, maximum cortical thickness, and border of the ALN.
J Cachexia Sarcopenia Muscle
February 2025
Center for Genomic Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Background: Diaphragm thickness is a potential marker of sarcopenia in addition to muscle mass and strength at extremities. We aimed to clarify the descriptive epidemiology and prognostic significance of diaphragm thickness in the general population.
Methods: The study participants were 3324 community residents (mean age: 61.
Ultrasound Med Biol
January 2025
Department of Circulation and Medical Imaging, Norwegian University of Science and Technology - NTNU, Trondheim, Norway; Health Research, SINTEF, Trondheim, Norway.
Objective: To develop and compare methods to automatically estimate regional ultrasound image quality for echocardiography separate from view correctness.
Methods: Three methods for estimating image quality were developed: (i) classic pixel-based metric: the generalized contrast-to-noise ratio (gCNR), computed on myocardial segments (region of interest) and left ventricle lumen (background), extracted by a U-Net segmentation model; (ii) local image coherence: the average local coherence as predicted by a U-Net model that predicts image coherence from B-mode ultrasound images at the pixel level; (iii) deep convolutional network: an end-to-end deep-learning model that predicts the quality of each region in the image directly. These methods were evaluated against manual regional quality annotations provided by three experienced cardiologists.
J Clin Med
January 2025
Department of Internal Medicine, Angiology, and Physical Medicine, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Batorego 15 St., 41-902 Bytom, Poland.
The interrelationship of thyroid volume and function with features of cardiovascular dysfunction has already been investigated but some aspects remain unclear, especially in terms of subclinical cardiovascular dysfunction in euthyroid patients. Intima-media thickness (IMT) measurement in ultrasound B-mode imaging in different vascular beds (most frequently within the common carotid artery) is one of the most important tools for the detection of subclinical atherosclerosis in both clinical practice and research. This article aimed to present the results of our research on the association between the thyroid evaluation parameters and the IMT measured in both the carotid and femoral arteries in euthyroid patients aged 18 to 65 years taking into account the influence of diabetes, hypertension, and excess body mass.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Department of Neurosurgery, Río Hortega University Hospital, 47014 Valladolid, Spain.
Intraoperative ultrasound (ioUS) provides real-time imaging during neurosurgical procedures, with advantages such as portability and cost-effectiveness. Accurate tumor segmentation has the potential to substantially enhance the interpretability of ioUS images; however, its implementation is limited by persistent challenges, including noise, artifacts, and anatomical variability. This study aims to develop a convolutional neural network (CNN) model for glioma segmentation in ioUS images via a multicenter dataset.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!