Stability of glyoxal- and methylglyoxal-modified hemoglobin on dried blood spot cards as analyzed by nanoflow liquid chromatography tandem mass spectrometry.

J Food Drug Anal

Department of Chemistry and Biochemistry, National Chung Cheng University, 168 University Road, Ming-Hsiung, Chia-Yi 62142, Taiwan.

Published: April 2019

Blood sampling by the dried blood spot (DBS) technique has become commonly applied in newborn screening. It is often used for analysis of small molecules, such as metabolites. Recently, DBS sampling has been applied for quantification of post-translational protein modifications. Glyoxal and methylglyoxal are two simple oxoaldehydes released from glycated proteins in the Maillard reaction. They are widely distributed in the environment (e.g. cigarette smoke) and found in foods and beverages. Glyoxal and methylglyoxal are shown to react with biomolecules including DNA and proteins. In this laboratory, we previously identified the sites of modification by these two oxoaldehydes in human hemoglobin and found that the extents of modification at certain sites of lysine and arginine residues are significantly higher in type 2 diabetes mellitus patients than in nondiabetic individuals. In this study, we examine the stability of these modifications of hemoglobin stored on DBS cards at room temperature or 4 °C in the ambient air. After hemoglobin was extracted from the DBS cards, it was digested by trypsin and analyzed by nanoflow liquid chromatography coupled with nanospray ionization tandem mass spectrometry. The results show that the extents of all these PTMs are stable within 14 and 21 days when stored on DBS at room temperature and at 4 °C, respectively. Extraction of globin from DBS cards is mostly advantageous for hemolytic blood samples. This assay is sensitive as only a quarter of a DBS card containing ca. 12 μL of blood is required. Thus, it is practically useful to measure the extents of glyoxal- and methylglyoxal-induced hemoglobin modifications from DBS cards.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9296192PMC
http://dx.doi.org/10.1016/j.jfda.2018.10.003DOI Listing

Publication Analysis

Top Keywords

dbs cards
16
dried blood
8
blood spot
8
analyzed nanoflow
8
nanoflow liquid
8
liquid chromatography
8
tandem mass
8
mass spectrometry
8
dbs
8
glyoxal methylglyoxal
8

Similar Publications

N-Acetyltyrosine as a Biomarker of Parenteral Nutrition Administration in First-Tier Newborn Screening Assays.

Int J Neonatal Screen

December 2024

Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, 4770 Buford Hwy NE, S110-3, Atlanta, GA 30341, USA.

Parenteral nutrition (PN) is a nutrient solution administered intravenously (IV) to premature babies. PN causes elevations of some amino acids in blood samples that are also biomarkers used in newborn screening (NBS). Therefore, PN status must be annotated by clinicians on dried blood spot (DBS) cards to reduce NBS laboratory burdens associated with potential false results; however, NBS laboratories continue to receive DBSs with misannotated PN status.

View Article and Find Full Text PDF

: Menstrual blood has recently emerged as a novel specimen for diagnostics, offering a non-invasive alternative to traditional blood testing methods. Despite the importance of vitamins and monitoring their levels in preventative healthcare measures, the feasibility of measuring them in menstrual blood has yet to be explored. In this study, we aimed to assess the potential of using menstrual blood for determining vitamin levels by comparing their levels in menstrual blood to those in matched capillary blood samples.

View Article and Find Full Text PDF

Testosterone is a critical hormone involved in regulating various physiological processes in both men and women. Accurate testosterone measurement is essential for diagnosing endocrine disorders such as hypogonadism and polycystic ovary syndrome and for routine testing. Traditionally, testosterone levels are measured using serum or plasma samples, which present challenges in sample collection, storage, and transport, particularly in resource-limited settings.

View Article and Find Full Text PDF

Background/objectives: Genetic newborn screening (NBS) has already entered the phase of common practice in many countries. In Germany, spinal muscular atrophy (SMA), severe combined immunodeficiency (SCID) and sickle cell disease (SCD) are currently a mandatory part of NBS. Here, we describe the experience of six years of genetic NBS including the prevalence of those three diseases in Germany.

View Article and Find Full Text PDF

Effective food safety monitoring requires a multi-step approach from farm to fork, involving different methods, ranging from convenient screening devices to sophisticated laboratory confirmatory testing. However, sample transportation to routine laboratories is time-consuming and expensive. Simplified on-site sampling followed by laboratory analysis offers a potential solution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!